Inter- and intraexaminer reliability of bitewing radiography and near-infrared light transillumination for proximal caries detection and assessment.

Litzenburger, Friederike; Heck, Katrin; Pitchika, Vinay; Neuhaus, Klaus W; Jost, Fabian Nicolas; Hickel, Reinhard; Jablonski-Momeni, Anahita; Welk, Alexander; Lederer, Alexander; Kühnisch, Jan (2018). Inter- and intraexaminer reliability of bitewing radiography and near-infrared light transillumination for proximal caries detection and assessment. Dento maxillo facial radiology, 47(3), p. 20170292. British Institute of Radiology 10.1259/dmfr.20170292

[img]
Preview
Text
dmfr.20170292.pdf - Published Version
Available under License Publisher holds Copyright.

Download (377kB) | Preview

OBJECTIVES

The purpose of this in vitro study was to evaluate the inter- and intraexaminer reliability of digital bitewing (DBW) radiography and near-infrared light transillumination (NIRT) for proximal caries detection and assessment in posterior teeth.

METHODS

From a pool of 85 patients, 100 corresponding pairs of DBW and NIRT images (~1/3 healthy, ~1/3 with enamel caries and ~1/3 with dentin caries) were chosen. 12 dentists with different professional status and clinical experience repeated the evaluation in two blinded cycles. Two experienced dentists provided a reference diagnosis after analysing all images independently. Statistical analysis included the calculation of simple (κ) and weighted Kappa (wκ) values as a measure of reliability. Logistic regression with a backward elimination model was used to investigate the influence of the diagnostic method, evaluation cycle, type of tooth, and clinical experience on reliability.

RESULTS

Altogether, inter- and intraexaminer reliability exhibited good to excellent κ and wκ values for DBW radiography (Inter: κ = 0.60/ 0.63; wκ = 0.74/0.76; Intra: κ = 0.64; wκ = 0.77) and NIRT (Inter: κ = 0.74/0.64; wκ = 0.86/0.82; Intra: κ = 0.68; wκ = 0.84). The backward elimination model revealed NIRT to be significantly more reliable than DBW radiography.

CONCLUSIONS

This study revealed a good to excellent inter- and intraexaminer reliability for proximal caries detection using DBW and NIRT images. The logistic regression analysis revealed significantly better reliability for NIRT. Additionally, the first evaluation cycle was more reliable according to the reference diagnoses.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry

UniBE Contributor:

Neuhaus, Klaus, Jost, Fabian Nicolas

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0250-832X

Publisher:

British Institute of Radiology

Language:

English

Submitter:

Hendrik Meyer-Lückel

Date Deposited:

20 Feb 2019 16:03

Last Modified:

05 Dec 2022 15:25

Publisher DOI:

10.1259/dmfr.20170292

PubMed ID:

29227160

BORIS DOI:

10.7892/boris.125292

URI:

https://boris.unibe.ch/id/eprint/125292

Actions (login required)

Edit item Edit item
Provide Feedback