van der Linden, Noreen; Wildi, Karin; Twerenbold, Raphael; Pickering, John W; Than, Martin; Cullen, Louise; Greenslade, Jaimi; Parsonage, William; Nestelberger, Thomas; Boeddinghaus, Jasper; Badertscher, Patrick; Rubini Giménez, Maria; Klinkenberg, Lieke J J; Bekers, Otto; Schöni, Aline; Keller, Dagmar I; Sabti, Zaid; Puelacher, Christian; Cupa, Janosch; Schumacher, Lukas; ... (2018). Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction. Circulation, 138(10), pp. 989-999. Lippincott Williams & Wilkins 10.1161/CIRCULATIONAHA.117.032003

[img]
Preview
Text
CIRCULATIONAHA.117.032003.pdf - Published Version
Available under License Publisher holds Copyright.

Download (221kB) | Preview

BACKGROUND

Combining 2 signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high-sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of acute myocardial infarction.

METHODS

The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio, and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected acute myocardial infarction. The optimal rule-out and rule-in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule-out was compared with the European Society of Cardiology 0/1 and 0/3 hour algorithms.

RESULTS

Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the European Society of Cardiology 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule-out criteria after the baseline blood sampling was limited (6% to 24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng/L) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34% to 41% in the original (sum: negative predictive value [NPV] 100% [95% confidence interval (CI), 99.5% to 100%]; product: NPV 100% [95% CI, 99.5% to 100%]) and in the validation cohort (sum: NPV 99.6% [95% CI, 99.0-99.9%]; product: NPV 99.4% [95% CI, 98.8-99.8%]). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule-out (40% to 43% ruled out; NPV original cohort 99.9% [95% CI, 99.2-100%]; NPV validation cohort 99.5% [95% CI, 98.9-99.8%]) and rule-in (positive predictive value [PPV] original cohort 74.4% [95% Cl, 69.6-78.8%]; PPV validation cohort 84.0% [95% Cl, 79.7-87.6%]).

CONCLUSIONS

New strategies combining hs-cTnI and hs-cTnT concentrations may significantly increase the number of patients eligible for very early and safe rule-out, but do not seem helpful for the rule-in of acute myocardial infarction.

CLINICAL TRIAL REGISTRATION

URL (APACE): https://www.clinicaltrial.gov . Unique identifier: NCT00470587. URL (ADAPT): www.anzctr.org.au . Unique identifier: ACTRN12611001069943.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Reichlin, Tobias Roman

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0009-7322

Publisher:

Lippincott Williams & Wilkins

Language:

English

Submitter:

Tobias Roman Reichlin

Date Deposited:

13 Mar 2019 12:38

Last Modified:

05 Dec 2022 15:26

Publisher DOI:

10.1161/CIRCULATIONAHA.117.032003

PubMed ID:

29691270

Uncontrolled Keywords:

combination diagnosis myocardial infarction troponins

BORIS DOI:

10.7892/boris.126341

URI:

https://boris.unibe.ch/id/eprint/126341

Actions (login required)

Edit item Edit item
Provide Feedback