Histological comparison of Platelet rich fibrin clots prepared by fixed-angle versus horizontal centrifugation.

Fujioka-Kobayashi, Masako; Kono, Michihide; Katagiri, Hiroki; Schaller, Benoît; Zhang, Yufeng; Sculean, Anton; Miron, Richard J. (2021). Histological comparison of Platelet rich fibrin clots prepared by fixed-angle versus horizontal centrifugation. Platelets, 32(3), pp. 413-419. Tayler & Francis 10.1080/09537104.2020.1754382

Full text not available from this repository.

Platelet-rich fibrin (PRF) is prepared from whole blood without any exogenous coagulation factors. Several preparation methods have now been introduced, particularly with differences in centrifugation parameters including g-force and time to improve their regenerative potential. Nevertheless, the centrifugation systems have not yet been clearly investigated for their influences on the PRF clot properties. The aim of the present study was to visually and histologically characterize the cell separation manner and blood cell localization on the whole PRF clots prepared by two different centrifugation system, fixed-angle and horizontal centrifugation. Leukocyte- and platelet-rich fibrin (L-PRF) was prepared on a fixed-angle centrifuge machine (IntraSpin, Intra-Lock, FL, USA) at 2700 rpm (~400 g at the RCF-clot; ~700 g at the RCF-max) for 12 min. The PRF prepared by horizontal centrifugation was prepared on a horizontal centrifugation (H-PRF) (Eppendorf 5702, Eppendorf, Germany) at 700 g at the RCF-max for 8 min. The cell morphology and localization were observed on the surface of PRF clots by scanning electron microscopy (SEM) and histologically by transaxial frozen sections by means of a film method. L-PRF clots demonstrated a sloped separation between the upper plasma and the bottom red blood cell (RBC) layers according to the angle of the rotor. Red dots were often observed on the distal walls of the tubes in the upper layers, consisting of aggregations of RBCs, leukocytes and platelets by SEM and histology. Clots produced on the horizontal centrifuge showed much smoother cell layer distribution/separation along the tube surfaces when compared to L-PRF. Horizontal centrifugation also demonstrated more evenly distributed platelets throughout the PRF clots when compared to L-PRF that gathered the majority of cells along the distal tube surface or within the buffy-coat region. In summary, it was found that horizontal centrifugation resulted in a more uniform blood cell separation of PRF clots when compared to the accumulation of cells gathered along the distal tube surfaces produced prepared by fixed-angle centrifugation. Future research is needed to evaluate the benefit of horizontal centrifugation in clinical practice.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Periodontology
04 Faculty of Medicine > Department of Head Organs and Neurology (DKNS) > Clinic of Craniomaxillofacial Surgery

UniBE Contributor:

Kobayashi, Masako (B), Katagiri, Hiroki, Schaller, Benoît, Sculean, Anton

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1369-1635

Publisher:

Tayler & Francis

Language:

English

Submitter:

Caroline Dominique Zürcher

Date Deposited:

07 Oct 2020 11:50

Last Modified:

29 Mar 2023 23:37

Publisher DOI:

10.1080/09537104.2020.1754382

PubMed ID:

32306811

Uncontrolled Keywords:

A-PRF fibrin l-PRF platelet-rich fibrin

URI:

https://boris.unibe.ch/id/eprint/146850

Actions (login required)

Edit item Edit item
Provide Feedback