Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy.

Schmitt, Daniela; Blanck, Oliver; Gauer, Tobias; Fix, Michael K.; Brunner, Thomas B; Fleckenstein, Jens; Loutfi-Krauss, Britta; Manser, Peter; Werner, Rene; Wilhelm, Maria-Lisa; Baus, Wolfgang W; Moustakis, Christos (2020). Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. Strahlentherapie und Onkologie, 196(5), pp. 421-443. Springer 10.1007/s00066-020-01583-2

[img]
Preview
Text
Schmitt2020_Article_TechnologicalQualityRequiremen (1).pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (587kB) | Preview

This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.

Item Type:

Journal Article (Review Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Radiation Oncology > Medical Radiation Physics

UniBE Contributor:

Fix, Michael, Manser, Peter

ISSN:

1439-099X

Publisher:

Springer

Language:

English

Submitter:

Ramona Wenholt

Date Deposited:

05 Nov 2020 16:43

Last Modified:

05 Dec 2022 15:41

Publisher DOI:

10.1007/s00066-020-01583-2

PubMed ID:

32211939

Uncontrolled Keywords:

FSRT Radiosurgery Recommendations SBRT SRS Technique

BORIS DOI:

10.7892/boris.147331

URI:

https://boris.unibe.ch/id/eprint/147331

Actions (login required)

Edit item Edit item
Provide Feedback