Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin?

Hahn, Robert G; Wüthrich, Patrick Yves; Zdolsek, Joachim H (2021). Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin? BMC anesthesiology, 21(1), p. 138. BioMed Central 10.1186/s12871-021-01351-4

[img]
Preview
Text
Can_perioperative_hemodilution_Wuethrich_BMC_Anesthesiology_2021.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

BACKGROUND

Trends in non-invasive measurements of blood hemoglobin (Hb) may be useful for identifying the need for transfusion in the perioperative period.

METHODS

Crystalloid fluid (5-20 mL/kg) was administered intravenously or by mouth to 30 volunteers and 33 surgical patients in five non-randomized clinical studies where Hb was measured on 915 occasions by non-invasive (Radical-7™) and invasive methodology. The hemodilution curves were compared by volume kinetic analysis and linear regression, with the slope and scattering of the data as key outcome measures.

RESULTS

The slope was 1.0, indicating unity between the two modes of measuring Hb when crystalloid fluid was infused in volunteers; however, only 40-45% of the variability in the non-invasive Hb could be explained by the invasive Hb. Patients undergoing major surgery, who showed the most pronounced hemodilution (median 24 g/L); non-invasive Hb explained 72% of the variability but indicated only half the magnitude of the invasive Hb changes (slope 0.48, P < 0.001 versus the volunteers). Simulations based on volume kinetic parameters from the volunteers showed 25% less plasma volume expansion after infusion when based on non-invasive as compared to invasive Hb, while no difference was found during infusion.

CONCLUSIONS

In volunteers the non-invasive Hb had good accuracy (low bias) but poor precision. In surgical patients the non-invasive Hb had good precision but systematically underestimated the hemodilution. Despite severe limitations, the non-invasive technology can be used to follow Hb trends during surgery if supported by occasional invasive measurements to assure acceptable quality of the hemodilution curve.

TRIAL REGISTRATIONS

ControlledTrials.gov NCT01195025, NCT01062776, NCT01458678, NCT03848507, and NCT01360333 on September 3, 2010, February 4, 2010, October 25, 2011, February 20, 2019, and May 25, 2011, respectively.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Intensive Care, Emergency Medicine and Anaesthesiology (DINA) > Clinic and Policlinic for Anaesthesiology and Pain Therapy

UniBE Contributor:

Wüthrich, Patrick Yves

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1471-2253

Publisher:

BioMed Central

Language:

English

Submitter:

Jeannie Wurz

Date Deposited:

28 Jun 2021 13:49

Last Modified:

05 Dec 2022 15:51

Publisher DOI:

10.1186/s12871-021-01351-4

PubMed ID:

33957864

Uncontrolled Keywords:

Hemoglobin Non-invasive measurement Point of care tests Pulse oximetry

BORIS DOI:

10.48350/156688

URI:

https://boris.unibe.ch/id/eprint/156688

Actions (login required)

Edit item Edit item
Provide Feedback