Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise.

Schwarz, Julia; Vidondo, Beatriz; Maninchedda, Ugo E; Sprick, Miriam; Schöpfer, Melina C; Cruz, Antonio M (2021). Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise. Frontiers in veterinary science, 8, p. 595455. Frontiers Media 10.3389/fvets.2021.595455

[img]
Preview
Text
fvets-08-595455.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

Objective: To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise. Animals: Thirty adult, sound and healthy French Montagne stallions. Procedures: Data collection was performed with six IMUs strapped to the distal, metacarpal, metatarsal and tibial regions of every horse. Per surface (treadmill, soft and hard ground) 10 stallions were trotted three times. Prior to the analysis done by six evaluators (three experienced, three inexperienced) the data was blinded and copied three times. For every analysis a minimum of five strides had to be selected. To assess the intra- and inter-evaluator reliability a selection of gait variables was used to calculate intra and inter correlation coefficients (ICCs) as well as variance partitioning coefficients (VPCs). Results: All of the tested gait variables showed high levels of reliability. There was no mentionable difference considering the correlation coefficients between the intra and inter reliability as well as between the three different surfaces. VPCs showed that the factor horse is by far the most responsible for any appearing variance. The experience of the evaluator had no influence on the results. Conclusions and Clinical Relevance: The software program tested in this study has a high inter- and intra-evaluator reliability under the chosen conditions for the selected variables and acts independent of the ground situation and the experience of the evaluator. On the condition of a correct application it has the potential to become a clinically relevant and reliable gait analysis tool.

Item Type:

Journal Article (Original Article)

Division/Institute:

05 Veterinary Medicine > Research Foci > Veterinary Public Health / Herd Health Management
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > ISME Equine Clinic Bern > ISME Equine Clinic, Internal medicine
05 Veterinary Medicine > Department of Clinical Research and Veterinary Public Health (DCR-VPH) > Veterinary Public Health Institute
05 Veterinary Medicine > Department of Clinical Research and Veterinary Public Health (DCR-VPH)

UniBE Contributor:

Vidondo Curras, Beatriz Teresa, Sprick, Miriam Maria Flurina

Subjects:

600 Technology
600 Technology > 630 Agriculture

ISSN:

2297-1769

Publisher:

Frontiers Media

Language:

English

Submitter:

Susanne Agnes Lerch

Date Deposited:

07 Mar 2022 15:50

Last Modified:

02 Mar 2023 23:36

Publisher DOI:

10.3389/fvets.2021.595455

PubMed ID:

33748204

Uncontrolled Keywords:

IMU gait horse kinematics reliability surface

BORIS DOI:

10.48350/166280

URI:

https://boris.unibe.ch/id/eprint/166280

Actions (login required)

Edit item Edit item
Provide Feedback