Antonacci, Donato; Del Fabbro, Massimo; Bollero, Patrizio; Stocchero, Michele; Jinno, Yohei; Canullo, Luigi (2023). Clinical effects of conventional and underprepared drilling preparation of the implant site based on bone density: A systematic review and meta-regression. Journal of prosthodontic research, 67(1), pp. 23-34. Japan Prosthodontic Society 10.2186/jpr.JPR_D_21_00275

[img]
Preview
Text
advpub_JPR_D_21_00275.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial (CC-BY-NC).

Download (3MB) | Preview

PURPOSE

There is no clinical consensus to determine the right balance between underpreparation and marginal bone level changes. The purpose of this systematic review and meta-regression was to investigate the influence of the type of drilling preparation of the implant site in relation to the bone mineral density on the clinical success, expressed in terms of the MBL and implant failure rate.

STUDY SELECTION

A thorough search was performed using the digital databases MEDLINE PubMed, EMBASE, and Cochrane Central Register of Controlled Trials by entering research lines or various combinations of free words. The main keywords used were "dental implants", "bone density", and "torque".

RESULTS

The mean bone resorption in the conventional preparation group was -0.43 (± 0.28) mm, whereas it was -0.80 (± 0.37) mm in the underprepared group. For the D1/D2/D3 bone group, the slope was significantly different from zero and linearity; the D4 bone group slope was not significantly different from zero and was almost parallel, although it was significantly different from linearity. The box and whiskers plot shows that the MBL in underprepared sites tended to be significantly higher with a higher variation than that in conventionally prepared sites.

CONCLUSION

Within its limits, our meta-regression analysis showed that MBL is influenced by the type of drilling preparation and bone mineral density. In particular, a lower MBL was observed in the D1 bone with conventional preparation than with underpreparation. Moreover, a greater implant-to-osteotomy site mismatch was positively associated with greater MBLs in the bone densities of D1/D2/D3.

Item Type:

Journal Article (Review Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Periodontology

UniBE Contributor:

Canullo, Luigi

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1883-9207

Publisher:

Japan Prosthodontic Society

Language:

English

Submitter:

Pubmed Import

Date Deposited:

25 Mar 2022 10:01

Last Modified:

11 Jan 2023 00:11

Publisher DOI:

10.2186/jpr.JPR_D_21_00275

PubMed ID:

35321991

Uncontrolled Keywords:

Bone density Bone drilling Conventional preparation Oral implantology Undersized preparation

BORIS DOI:

10.48350/168035

URI:

https://boris.unibe.ch/id/eprint/168035

Actions (login required)

Edit item Edit item
Provide Feedback