van Leeuwen, B J; Dijkstra, P U; Dieters, J A; Verbeek, H P J; Kuijpers-Jagtman, A M; Ren, Y (2022). Effect of voxel size in cone-beam computed tomography on surface area measurements of dehiscences and fenestrations in the lower anterior buccal region. Clinical oral investigations, 26(9), pp. 5663-5672. Springer 10.1007/s00784-022-04521-x
|
Text
Leeuwen2022_Article_EffectOfVoxelSizeInCone-beamCo.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (1MB) | Preview |
OBJECTIVES
This study aims to assess whether different voxel sizes in cone-beam computed tomography (CBCT) affected surface area measurements of dehiscences and fenestrations in the mandibular anterior buccal region.
MATERIALS AND METHODS
Nineteen dry human mandibles were scanned with a surface scanner (SS). Wax was attached to the mandibles as a soft tissue equivalent. Three-dimensional digital models were generated with a CBCT unit, with voxel sizes of 0.200 mm (VS200), 0.400 mm (VS400), and 0.600 mm (VS600). The buccal surface areas of the six anterior teeth were measured (in mm2) to evaluate areas of dehiscences and fenestrations. Differences between the CBCT and SS measurements were determined in a linear mixed model analysis.
RESULTS
The mean surface area per tooth was 88.3 ± 24.0 mm2, with the SS, and 94.6 ± 26.5 (VS200), 95.1 ± 27.3 (VS400), and 96.0 ± 26.5 (VS600), with CBCT scans. Larger surface areas resulted in larger differences between CBCT and SS measurements (- 0.1 β, SE = 0.02, p < 0.001). Deviations from SS measurements were larger with VS600, compared to VS200 (1.3 β, SE = 0.05, P = 0.009). Fenestrations were undetectable with CBCT.
CONCLUSIONS
CBCT imaging magnified the surface area of dehiscences in the anterior buccal region of the mandible by 7 to 9%. The larger the voxel size, the larger the deviation from SS measurements. Fenestrations were not detectable with CBCT.
CLINICAL RELEVANCE
CBCT is an acceptable tool for measuring dehiscences but not fenestrations. However, CBCT overestimates the size of dehiscences, and the degree of overestimation depends on the actual dehiscence size and CBCT voxel size employed.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine > Department of Orthodontics |
UniBE Contributor: |
Kuijpers-Jagtman, Anne-Marie |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1436-3771 |
Publisher: |
Springer |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
09 May 2022 09:18 |
Last Modified: |
05 Dec 2022 16:19 |
Publisher DOI: |
10.1007/s00784-022-04521-x |
PubMed ID: |
35513582 |
Uncontrolled Keywords: |
Accuracy Cone-beam computed tomography Dehiscence Fenestration Reliability |
BORIS DOI: |
10.48350/169846 |
URI: |
https://boris.unibe.ch/id/eprint/169846 |