Nonlesional Sources of Contrast Enhancement on Postgadolinium "Black-Blood" 3D T1-SPACE Images in Patients with Multiple Sclerosis.

Danieli, L; Roccatagliata, L; Distefano, D; Prodi, E; Riccitelli, G C; Diociasi, A; Carmisciano, L; Cianfoni, A; Bartalena, T; Kaelin-Lang, A; Gobbi, C; Zecca, C; Pravatà, E (2022). Nonlesional Sources of Contrast Enhancement on Postgadolinium "Black-Blood" 3D T1-SPACE Images in Patients with Multiple Sclerosis. AJNR. American journal of neuroradiology, 43(6), pp. 872-880. American Society of Neuroradiology 10.3174/ajnr.A7529

[img] Text
ajnr.A7529.full.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB)

BACKGROUND AND PURPOSE

We hypothesized that 3D T1-TSE "black-blood" images may carry an increased risk of contrast-enhancing lesion misdiagnosis in patients with MS because of the misinterpretation of intraparenchymal vein enhancement. Thus, the occurrence of true-positive and false-positive findings was compared between standard MPRAGE and volumetric interpolated brain examination techniques.

MATERIALS AND METHODS

Sampling perfection with application-optimized contrasts by using different flip-angle evolution (SPACE) images obtained from 232 patients with MS, clinically isolated syndrome, or radiologically isolated syndrome were compared with standard MPRAGE and volumetric interpolated brain examination images. The intraparenchymal vein contrast-to-noise ratio was estimated at the level of the thalami. Contrast-enhancing lesions were blindly detected by 2 expert readers and 1 beginner reader. True- and false-positives were determined by senior readers' consensus. True-positive and false-positive frequency differences and patient-level diagnosis probability were tested with the McNemar test and OR. The contrast-to-noise ratio and morphology were compared using the Mann-Whitney U and χ2 tests.

RESULTS

The intraparenchymal vein contrast-to-noise ratio was higher in SPACE than in MPRAGE and volumetric interpolated brain examination images (P < .001, both). There were 66 true-positives and 74 false-positives overall. SPACE detected more true-positive and false-positive results (P range < .001-.07) but did not increase the patient's true-positive likelihood (OR = 1 1.29, P = .478-1). However, the false-positive likelihood was increased (OR = 3.03-3.55, P = .008-.027). Venous-origin false-positives (n = 59) with contrast-to-noise ratio and morphology features similar to small-sized (≤14 mm3 P = .544) true-positives occurred more frequently in SPACE images (P < .001).

CONCLUSIONS

Small intraparenchymal veins may confound the diagnosis of enhancing lesions on postgadolinium black-blood SPACE images.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic and Interventional Neuroradiology

UniBE Contributor:

Cianfoni, Alessandro

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1936-959X

Publisher:

American Society of Neuroradiology

Language:

English

Submitter:

Pubmed Import

Date Deposited:

30 May 2022 15:19

Last Modified:

05 Dec 2022 16:20

Publisher DOI:

10.3174/ajnr.A7529

PubMed ID:

35618421

BORIS DOI:

10.48350/170287

URI:

https://boris.unibe.ch/id/eprint/170287

Actions (login required)

Edit item Edit item
Provide Feedback