Efficacy of mechanical/physical approaches for implant surface decontamination in nonsurgical submarginal instrumentation of peri-implantitis. A systematic review.

Cosgarea, R; Roccuzzo, A; Jepsen, K; Sculean, A; Jepsen, S; Salvi, G E (2023). Efficacy of mechanical/physical approaches for implant surface decontamination in nonsurgical submarginal instrumentation of peri-implantitis. A systematic review. Journal of clinical periodontology, 50 Suppl 26, pp. 188-211. Wiley 10.1111/jcpe.13762

[img]
Preview
Text
J_Clinic_Periodontology_-_2022_-_Cosgarea_-_Efficacy_of_mechanical_physical_approaches_for_implant_surface_decontamination.pdf - Accepted Version
Available under License Publisher holds Copyright.

Download (737kB) | Preview

AIM

To evaluate the efficacy of non-surgical submarginal peri-implant instrumentation with mechanical/physical decontamination, compared to non-surgical submarginal instrumentation alone/with placebo decontamination, in patients with peri-implantitis.

MATERIALS AND METHODS

Three focused questions were addressed and a systematic search for randomized controlled clinical trials (RCTs), controlled clinical trials and prospective cohort studies with definitions of peri-implantitis and a minimal follow-up of 6 months was conducted. The main outcome variables were reduction in pocket probing depth (PD) and bleeding on probing (BOP). Suppuration on probing, marginal peri-implant bone level changes, patient related outcomes and adverse events, implant survival, treatment success and disease resolution were assessed as secondary outcomes.

RESULTS

Out of 2398 findings, full-text articles were assessed for eligibility and nine (n=9 RCTs) were included in the present review. Five studies evaluated the effects of various laser types and in four studies efficacy of air-abrasive mechanisms and of a novel ultrasonic device was determined. At 6 months, PD reductions were observed in 9 studies but only Er,Cr:YSGG laser showed statistically significant higher reductions compared to the control group. BOP was statistically significantly reduced at 6 months in 2 studies following application of Er:YAG laser compared to controls. One study reported statistically significant reduction in BOP following application of air-polishing device as compared to control treatment. No statistically significant differences between treatment groups were reported for the secondary outcome variables. Due to the large heterogeneity of study designs, no meta-analysis was performed.

CONCLUSION

Available evidence on efficacy of non-surgical submarginal peri-implant instrumentation with mechanical/physical decontamination is limited by a low number of controlled studies and a high heterogeneity of study protocols. Clinical and patient-reported benefits remain to be demonstrated.

Item Type:

Journal Article (Review Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Periodontology

UniBE Contributor:

Roccuzzo, Andrea, Sculean, Anton, Salvi, Giovanni Edoardo

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1600-051X

Publisher:

Wiley

Language:

English

Submitter:

Pubmed Import

Date Deposited:

06 Jan 2023 13:55

Last Modified:

24 Dec 2023 00:25

Publisher DOI:

10.1111/jcpe.13762

PubMed ID:

36550060

Uncontrolled Keywords:

air polishing laser non-surgical therapy peri-implant diseases peri-implantitis submarginal instrumentation

BORIS DOI:

10.48350/176424

URI:

https://boris.unibe.ch/id/eprint/176424

Actions (login required)

Edit item Edit item
Provide Feedback