Performance of two-dimensional shear wave elastography and transient elastography compared to liver biopsy for staging of liver fibrosis.

Kovatsch, Audrey; Honcharova-Biletska, Hanna; Segna, Daniel; Steigmiller, Klaus; Blümel, Sena; Deibel, Rudolf A; Kühlewindt, Tobias; Leinenkugel, Georg; Müller, Sandra; Furrer, Eva; Schawkat, Khoschy; Reiner, Cäcilia S; Weber, Achim; Müllhaupt, Beat; Scharl, Michael; Gubler, Christoph; Jüngst, Christoph (2023). Performance of two-dimensional shear wave elastography and transient elastography compared to liver biopsy for staging of liver fibrosis. European journal of clinical investigation, 53(7), e13980. Wiley 10.1111/eci.13980

[img]
Preview
Text
Eur_J_Clin_Investigation_-_2023_-_Kovatsch_-_Performance_of_two_dimensional_shear_wave_elastography_and_transient.pdf - Accepted Version
Available under License Publisher holds Copyright.

Download (1MB) | Preview

BACKGROUND

Staging of liver fibrosis traditionally relied on liver histology, however transient elastography (TE) and more recently two-dimensional shear wave elastography (2D-SWE) evolved to non-invasive alternatives. Hence, we evaluated the diagnostic accuracy of 2D-SWE assessed by the Canon Aplio i800 ultrasound system using liver biopsy as reference and compared the performance to TE.

METHODS

In total, 108 adult patients with chronic liver disease undergoing liver biopsy, 2D-SWE and TE were enrolled prospectively at the University Hospital Zurich. Diagnostic accuracies were evaluated using the area under the receiver operating characteristic (AUROC) analysis, and optimal cutoff values by Youden's index RESULTS: Diagnostic accuracy of 2D-SWE was good for significant (≥F2; AUROC 85.2%, 95% confidence interval (95%CI):76.2-91.2%) as well as severe fibrosis (≥F3; AUROC 86.8%, 95%CI:78.1-92.4%) and excellent for cirrhosis (AUROC 95.6%, 95%CI:89.9-98.1%), compared to histology. TE performed equally well (significant fibrosis: 87.5%, 95%CI:77.7-93.3%; severe fibrosis: 89.7%, 95%CI:82.0-94.3%; cirrhosis: 96%, 95%CI:90.4-98.4%), and accuracy was not statistically different to 2D-SWE. 2D-SWE optimal cutoff values were 6.5, 9.8 and 13.1 kPa for significant fibrosis, severe fibrosis, and cirrhosis, respectively.

CONCLUSIONS

Performance of 2D-SWE was good to excellent and well comparable with TE, supporting the application of this 2D-SWE system in the diagnostic workup of chronic liver disease.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Gastro-intestinal, Liver and Lung Disorders (DMLL) > Clinic of Visceral Surgery and Medicine

UniBE Contributor:

Segna, Daniel

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1365-2362

Publisher:

Wiley

Language:

English

Submitter:

Pubmed Import

Date Deposited:

08 Mar 2023 11:18

Last Modified:

09 Mar 2024 00:25

Publisher DOI:

10.1111/eci.13980

PubMed ID:

36880934

Uncontrolled Keywords:

2D-SWE chronic liver disease liver stiffness measurement non-invasive shear wave elastography transient elastography

BORIS DOI:

10.48350/179673

URI:

https://boris.unibe.ch/id/eprint/179673

Actions (login required)

Edit item Edit item
Provide Feedback