Wagener, Max; Reuthebuch, Oliver; Heg, Dik; Tüller, David; Ferrari, Enrico; Grünenfelder, Jürg; Huber, Christoph; Moarof, Igal; Muller, Olivier; Nietlispach, Fabian; Noble, Stéphane; Roffi, Marco; Taramasso, Maurizio; Templin, Christian; Toggweiler, Stefan; Wenaweser, Peter; Windecker, Stephan; Stortecky, Stefan; Jeger, Raban (2023). Clinical Outcomes in High-Gradient, Classical Low-Flow, Low-Gradient, and Paradoxical Low-Flow, Low-Gradient Aortic Stenosis After Transcatheter Aortic Valve Implantation: A Report From the SwissTAVI Registry. Journal of the American Heart Association, 12(12), e029489. American Heart Association 10.1161/JAHA.123.029489
|
Text
JAHA.123.029489.pdf - Published Version Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND). Download (812kB) | Preview |
Background In view of the rising global burden of severe symptomatic aortic stenosis, its early recognition and treatment is key. Although patients with classical low-flow, low-gradient (C-LFLG) aortic stenosis have higher rates of death after transcatheter aortic valve implantation (TAVI) when compared with patients with high-gradient (HG) aortic stenosis, there is conflicting evidence on the death rate in patients with severe paradoxical low-flow, low-gradient (P-LFLG) aortic stenosis. Therefore, we aimed to compare outcomes in real-world patients with severe HG, C-LFLG, and P-LFLG aortic stenosis undergoing TAVI. Methods and Results Clinical outcomes up to 5 years were addressed in the 3 groups of patients enrolled in the prospective, national, multicenter SwissTAVI registry. A total of 8914 patients undergoing TAVI at 15 heart valve centers in Switzerland were analyzed for the purpose of this study. We observed a significant difference in time to death at 1 year after TAVI, with the lowest observed in HG (8.8%) aortic stenosis, followed by P-LFLG (11.5%; hazard ratio [HR], 1.35 [95% CI, 1.16-1.56]; P<0.001) and C-LFLG (19.8%; HR, 1.93 [95% CI, 1.64-2.26]; P<0.001) aortic stenosis. Cardiovascular death showed similar differences between the groups. At 5 years, the all-cause death rate was 44.4% in HG, 52.1% in P-LFLG (HR, 1.35 [95% CI, 1.23-1.48]; P<0.001), and 62.8% in C-LFLG aortic stenosis (HR, 1.7 [95% CI, 1.54-1.88]; P<0.001). Conclusions Up to 5 years after TAVI, patients with P-LFLG have higher death rates than patients with HG aortic stenosis but lower death rates than patients with C-LFLG aortic stenosis.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology 04 Faculty of Medicine > Pre-clinic Human Medicine > Department of Clinical Research (DCR) |
UniBE Contributor: |
Heg, Dierik Hans, Windecker, Stephan, Stortecky, Stefan |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
2047-9980 |
Publisher: |
American Heart Association |
Funders: |
[116] Swiss Heart Foundation = Schweizerische Herzstiftung |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
12 Jun 2023 13:04 |
Last Modified: |
20 Feb 2024 14:15 |
Publisher DOI: |
10.1161/JAHA.123.029489 |
PubMed ID: |
37301760 |
Uncontrolled Keywords: |
SwissTAVI low‐flow, low‐gradient outcomes in aortic stenosis transcatheter aortic valve implantation valvular heart disease |
BORIS DOI: |
10.48350/183315 |
URI: |
https://boris.unibe.ch/id/eprint/183315 |