Smolders, Andreas Johan; Choulilitsa, Evangelia; Czerska, Katarzyna; Bizzocchi, Nicola; Krcek, Reinhardt; Lomax, Antony John; Weber, Damien Charles; Albertini, Francesca (2023). Dosimetric comparison of autocontouring techniques for online adaptive proton therapy. Physics in medicine and biology, 68(17) IOP Publishing 10.1088/1361-6560/ace307
|
Text
Smolders_et_al_2023_Phys._Med._Biol._10.1088_1361-6560_ace307.pdf - Accepted Version Available under License Creative Commons: Attribution (CC-BY). Download (1MB) | Preview |
anatomical and daily set-up uncertainties impede high precision delivery of proton therapy. With online adaptation, the daily plan is reoptimized on an image taken shortly before the treatment, reducing these uncertainties and, hence, allowing a more accurate delivery. This reoptimization requires target and organs-at-risk (OAR) contours on the daily image, which need to be delineated automatically since manual contouring is too slow. Whereas multiple methods for autocontouring exist, none of them are fully accurate, which affects the daily dose. This work aims to quantify the magnitude of this dosimetric effect for four contouring techniques.

Approach: plans reoptimized on automatic contours are compared with plans reoptimized on manual contours. The methods include rigid and deformable registration (DIR), deep-learning based segmentation and patient-specific segmentation.

Results: it was found that independently of the contouring method, the dosimetric influence of using automatic OAR contours is small (< 5% prescribed dose in most cases), with DIR yielding the best results. Contrarily, the dosimetric effect of using the automatic target contour was larger (> 5% prescribed dose in most cases), indicating that manual verification of that contour remains necessary. However, when compared to non-adaptive therapy, the dose differences caused by automatically contouring the target were small and target coverage was improved, especially for DIR.

Significance: the results show that manual adjustment of OARs is rarely necessary and that several autocontouring techniques are directly usable. Contrarily, manual adjustment of the target is important. This allows prioritizing tasks during time-critical online adaptive proton therapy and therefore supports its further clinical implementation.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Radiation Oncology |
UniBE Contributor: |
Krcek, Reinhardt |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1361-6560 |
Publisher: |
IOP Publishing |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
30 Jun 2023 10:25 |
Last Modified: |
12 Aug 2023 00:16 |
Publisher DOI: |
10.1088/1361-6560/ace307 |
PubMed ID: |
37385266 |
Uncontrolled Keywords: |
adaptive radiotherapy contour propagation deformable image registration head and neck cancer lung cancer proton therapy |
BORIS DOI: |
10.48350/184282 |
URI: |
https://boris.unibe.ch/id/eprint/184282 |