Roccuzzo, Andrea; Morandini, Michele; Stähli, Alexandra; Imber, Jean-Claude; Sculean, Anton; Salvi, Giovanni Edoardo (2023). Clinical and radiographic outcomes of implant-supported zirconia fixed dental prostheses with cantilever extension: A proof-of-principle study with a follow-up of at least 1 year. Clinical oral implants research, 34(10), pp. 1073-1082. Wiley-Blackwell 10.1111/clr.14138

[img]
Preview
Text
Clinical_Oral_Implants_Res_-_2023_-_Roccuzzo_-_Clinical_and_radiographic_outcomes_of_implant_supported_zirconia_fixed.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial (CC-BY-NC).

Download (1MB) | Preview

OBJECTIVES

To test the reliability of full zirconia implant-supported fixed dental prostheses with cantilever extension (FDPCs) after at least 1 year of function.

MATERIALS AND METHODS

Thirty-five patients in need of implant-supported single unit crowns (SUC) and FDPCs in posterior areas were enrolled. After implant placement, patients were rehabilitated with screw-retained full-zirconia FDPCs. Implant survival rate, pocket probing depth (PPD), presence/absence of bleeding on probing (BoP), and presence/absence of mechanical/technical complications were recorded. Mesial and distal radiographic marginal bone levels (mBLs) from baseline (i.e., recall appointment 3-6 months after implant loading [T0]) to the follow-up examination (i.e., latest recall appointment after at least 12 months after T0 [T1]), were calculated.

RESULTS

Thirty patients with 34 FDPCs (31 SUCs and 3 FDPs) supported by 37 implants were available for analysis after a mean loading time of 2.6 ± 1.5 years (range: 13-87 months). No implants were lost. MBLs and mean PPD values did not change statistically significantly from T0 to T1 from 0.92 mm ± 0.42 to 0.96 mm ± 0.38 (95% CI: -0.07/0.17; p = .418) and from 2.99 mm ± 0.70 to 3.27 mm ± 0.71 (95% CI: -0.11/0.68; p = .25) respectively. Peri-implant mucositis was diagnosed in 22 cases. Screw-loosening and zirconia chipping occurred 1× in 4 patients.

CONCLUSION

Within the limitations of the present proof-of-principle study, the use of full-zirconia FDPCs in posterior areas seems a valid and safe short-term treatment option.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Periodontology
04 Faculty of Medicine > School of Dental Medicine
04 Faculty of Medicine > School of Dental Medicine > Periodontics Research
04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry

UniBE Contributor:

Roccuzzo, Andrea, Morandini, Michele Ettore Rodolfo, Stähli, Alexandra Beatrice, Imber, Jean-Claude, Sculean, Anton, Salvi, Giovanni Edoardo

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0905-7161

Publisher:

Wiley-Blackwell

Language:

English

Submitter:

Pubmed Import

Date Deposited:

25 Jul 2023 09:07

Last Modified:

10 Oct 2023 00:13

Publisher DOI:

10.1111/clr.14138

PubMed ID:

37485971

Uncontrolled Keywords:

biological complications bone loss cantilever extension dental implants fixed dental prostheses technical complications

BORIS DOI:

10.48350/185048

URI:

https://boris.unibe.ch/id/eprint/185048

Actions (login required)

Edit item Edit item
Provide Feedback