Collateral-flow measurements in humans by myocardial contrast echocardiography: validation of coronary pressure-derived collateral-flow assessment

Vogel, Rolf; Zbinden, Rainer; Indermühle, Andreas; Windecker, Stephan; Meier, Bernhard; Seiler, Christian (2006). Collateral-flow measurements in humans by myocardial contrast echocardiography: validation of coronary pressure-derived collateral-flow assessment. European Heart Journal, 27(2), pp. 157-65. Oxford: Oxford University Press 10.1093/eurheartj/ehi585

[img]
Preview
Text
ehi585.pdf - Published Version
Available under License Publisher holds Copyright.

Download (574kB) | Preview

AIMS: Myocardial blood flow (MBF) is the gold standard to assess myocardial blood supply and, as recently shown, can be obtained by myocardial contrast echocardiography (MCE). The aims of this human study are (i) to test whether measurements of collateral-derived MBF by MCE are feasible during elective angioplasty and (ii) to validate the concept of pressure-derived collateral-flow assessment. METHODS AND RESULTS: Thirty patients with stable coronary artery disease underwent MCE of the collateral-receiving territory during and after angioplasty of 37 stenoses. MCE perfusion analysis was successful in 32 cases. MBF during and after angioplasty varied between 0.060-0.876 mL min(-1) g(-1) (0.304+/-0.196 mL min(-1) g(-1)) and 0.676-1.773 mL min(-1) g(-1) (1.207+/-0.327 mL min(-1) g(-1)), respectively. Collateral-perfusion index (CPI) is defined as the rate of MBF during and after angioplasty varied between 0.05 and 0.67 (0.26+/-0.15). During angioplasty, simultaneous measurements of mean aortic pressure, coronary wedge pressure, and central venous pressure determined the pressure-derived collateral-flow index (CFI(p)), which varied between 0.04 and 0.61 (0.23+/-0.14). Linear-regression analysis demonstrated an excellent agreement between CFI(p) and CPI (y=0.88 x +0.01; r(2)=0.92; P<0.0001). CONCLUSION: Collateral-derived MBF measurements by MCE during angioplasty are feasible and proved that the pressure-derived CFI exactly reflects collateral relative to normal myocardial perfusion in humans.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Vogel, Rolf, Windecker, Stephan, Meier, Bernhard, Seiler, Christian

ISSN:

0195-668X

ISBN:

16207739

Publisher:

Oxford University Press

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 14:46

Last Modified:

05 Dec 2022 14:14

Publisher DOI:

10.1093/eurheartj/ehi585

PubMed ID:

16207739

Web of Science ID:

000234436800010

BORIS DOI:

10.7892/boris.19044

URI:

https://boris.unibe.ch/id/eprint/19044 (FactScience: 1412)

Actions (login required)

Edit item Edit item
Provide Feedback