Seitz, Pascal; Lötscher, Fabian; Bucher, Susana; Bütikofer, Lukas; Maurer, Britta; Hakim, Arsany; Seitz, Luca (2024). Ultrasound intima-media thickness cut-off values for the diagnosis of giant cell arteritis using a dual clinical and MRI reference standard and cardiovascular risk stratification. Frontiers in medicine, 11(1389655) Frontiers 10.3389/fmed.2024.1389655

[img]
Preview
Text
fmed-11-1389655.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (2MB) | Preview

OBJECTIVES

To derive segmental cut-off values and measures of diagnostic accuracy for the intima-media thickness of compressed temporal artery segments for the diagnosis of giant cell arteritis (GCA) on the patient level. To examine the influence of cardiovascular risk.

METHODS

Retrospectively, patients evaluated for GCA with an ultrasound of the temporal arteries and an MRI of the head, including a T1-fatsat-black blood (T1-BB) sequence, were identified and classified based on cardiovascular risk and a dual reference standard of T1-BB on the segmental level and the clinical diagnosis on the patient level. Intima-media thickness of the common superficial temporal artery (CSTA), frontal and parietal branches (FB, PB) were measured by compression technique. Statistically and clinically optimal (specificity of approx. 90% for the patient level) cut-offs were derived. Diagnostic accuracy was evaluated on the patient level.

RESULTS

The population consisted of 144 patients, 74 (51.4%) with and 70 (48.6%) without GCA. The statistically optimal cut-offs were 0.86 mm, 0.68 mm and 0.67 mm for the CSTA, the FB and PB, respectively. On the patient level sensitivity and specificity were 86.5 and 81.4%. Clinically optimal cut-offs were 1.01 mm, 0.82 mm and 0.69 mm and showed a sensitivity of 79.7% and a specificity of 90.0%. For patients without high cardiovascular risk, statistically optimal cut-offs showed a sensitivity of 89.6% and a specificity of 90.5%.

CONCLUSION

Newly derived ultrasound intima-media thickness cut-offs with a dual reference standard show high diagnostic accuracy on the patient level for the diagnosis of GCA, particularly in patients without high cardiovascular risk.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Dermatology, Urology, Rheumatology, Nephrology, Osteoporosis (DURN) > Clinic of Rheumatology and Immunology
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic and Interventional Neuroradiology

UniBE Contributor:

Seitz, Pascal, Lötscher, Fabian, Bütikofer, Lukas (B), Maurer, Britta, Hakim, Arsany, Seitz, Luca Fabio

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2296-858X

Publisher:

Frontiers

Language:

English

Submitter:

Pubmed Import

Date Deposited:

25 Apr 2024 10:53

Last Modified:

25 Apr 2024 11:03

Publisher DOI:

10.3389/fmed.2024.1389655

PubMed ID:

38654833

Uncontrolled Keywords:

T1-fatsat-black-blood cardiovascular risk cut-off giant cell arteritis intima-media thickness ultrasound vasculitis vessel wall MRI

BORIS DOI:

10.48350/196214

URI:

https://boris.unibe.ch/id/eprint/196214

Actions (login required)

Edit item Edit item
Provide Feedback