Whole-body MRI of multiple myeloma: comparison of different MRI sequences in assessment of different growth patterns

Weininger, Markus; Lauterbach, Brigitte; Knop, Stefan; Pabst, Thomas; Kenn, Werner; Hahn, Dietbert; Beissert, Matthias (2009). Whole-body MRI of multiple myeloma: comparison of different MRI sequences in assessment of different growth patterns. European journal of radiology, 69(2), pp. 339-45. Stuttgart: Thieme 10.1016/j.ejrad.2007.10.025

Full text not available from this repository. (Request a copy)

PURPOSE: To determine sensitivity, specificity and inter-observer variability of different whole-body MRI (WB-MRI) sequences in patients with multiple myeloma (MM). METHODS AND MATERIALS: WB-MRI using a 1.5T MRI scanner was performed in 23 consecutive patients (13 males, 10 females; mean age 63+/-12 years) with histologically proven MM. All patients were clinically classified according to infiltration (low-grade, n=7; intermediate-grade, n=7; high-grade, n=9) and to the staging system of Durie and Salmon PLUS (stage I, n=12; stage II, n=4; stage III, n=7). The control group consisted of 36 individuals without malignancy (25 males, 11 females; mean age 57+/-13 years). Two observers independently evaluated the following WB-MRI sequences: T1w-TSE (T1), T2w-TIRM (T2), and the combination of both sequences, including a contrast-enhanced T1w-TSE with fat-saturation (T1+/-CE/T2). They had to determine growth patterns (focal and/or diffuse) and the MRI sequence that provided the highest confidence level in depicting the MM lesions. Results were calculated on a per-patient basis. RESULTS: Visual detection of MM was as follows: T1, 65% (sensitivity)/85% (specificity); T2, 76%/81%; T1+/-CE/T2, 67%/88%. Inter-observer variability was as follows: T1, 0.3; T2, 0.55; T1+/-CE/T2, 0.55. Sensitivity improved depending on infiltration grade (T1: 1=60%; 2=36%; 3=83%; T2: 1=70%; 2=71%; 3=89%; T1+/-CE/T2: 1=50%; 2=50%; 3=89%) and clinical stage (T1: 1=58%; 2=63%; 3=79%; T2: 1=58%; 2=88%; 3=100%; T1+/-CE/T2: 1=50%; 2=63%; 3=100%). T2w-TIRM sequences achieved the best reliability in depicting the MM lesions (65% in the mean of both readers). CONCLUSIONS: T2w-TIRM sequences achieved the highest level of sensitivity and best reliability, and thus might be valuable for initial assessment of MM. For an exact staging and grading the examination protocol should encompass unenhanced and enhanced T1w-MRI sequences, in addition to T2w-TIRM.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Medical Oncology

UniBE Contributor:

Pabst, Thomas Niklaus

ISSN:

0720-048X

ISBN:

18096344

Publisher:

Thieme

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 14:53

Last Modified:

02 Mar 2023 23:22

Publisher DOI:

10.1016/j.ejrad.2007.10.025

PubMed ID:

18096344

Web of Science ID:

000264220600020

URI:

https://boris.unibe.ch/id/eprint/22379 (FactScience: 34468)

Actions (login required)

Edit item Edit item
Provide Feedback