Matt, Peter; Winkler, Bernhard; Carrel, Thierry; Eckstein, Friedrich (2010). Plicated patch repair for acquired Gerbode defect involving the tricuspid valve. Annals of thoracic surgery, 89(2), pp. 643-5. New York, N.Y.: Elsevier 10.1016/j.athoracsur.2009.04.095
Full text not available from this repository.Gerbode's defect, a left ventricular-to-right atrial communication, with involvement of the tricuspid valve acquired after bacterial endocarditis can be challenging to repair. We report a modified technique for a shunt closure and reconstruction of the tricuspid valve using a plicated bovine pericardial patch. Combining such a repair with a left ventricular patch resulted in a complete defect closure and competent tricuspid valve without regurgitation.