Stortecky, Stefan; Heg, Dik; Glökler, Steffen; Wenaweser, Peter Martin; Windecker, Stephan; Büllesfeld, Lutz (2014). Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement. EuroIntervention, 10(3), pp. 339-346. Europa Digital & Publishing
|
Text
Stortecky EuroIntervention 2014.pdf - Published Version Available under License Publisher holds Copyright. Download (1MB) | Preview |
Aims: To evaluate the accuracy and reproducibility of aortic annulus sizing using a multislice computed tomography (MSCT) based aortic root reconstruction tool compared with conventional imaging among patients evaluated for transcatheter aortic valve replacement (TAVR). Methods and results: Patients referred for TAVR underwent standard preprocedural assessment of aortic annulus parameters using MSCT, angiography and transoesophageal echocardiography (TEE). Three-dimensional (3-D) reconstruction of MSCT images of the aortic root was performed using 3mensio (3mensio Medical Imaging BV, Bilthoven, The Netherlands), allowing for semi-automated delineation of the annular plane and assessment of annulus perimeter, area, maximum, minimum and virtual diameters derived from area and perimeter (aVD and pVD). A total of 177 patients were enrolled. We observed a good inter-observer variability of 3-D reconstruction assessments with concordance coefficients for agreement of 0.91 (95% CI: 0.87-0.93) and 0.91 (0.88-0.94) for annulus perimeter and area assessments, respectively. 3-D derived pVD and aVD correlated very closely with a concordance coefficient of 0.97 (0.96-0.98) with a mean difference of 0.5±0.3 mm (pVD-aVD). 3-D derived pVD showed the best, but moderate concordance with diameters obtained from coronal MSCT (0.67, 0.56-0.75; 0.3±1.8 mm), and the lowest concordance with diameters obtained from TEE (0.42, 0.31-0.52; 1.9±1.9 mm). Conclusions: MSCT-based 3-D reconstruction of the aortic annulus using the 3mensio software enables accurate and reproducible assessment of aortic annulus dimensions.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Pre-clinic Human Medicine > Department of Clinical Research (DCR) 04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology |
UniBE Contributor: |
Stortecky, Stefan, Heg, Dierik Hans, Glökler, Steffen, Wenaweser, Peter Martin, Windecker, Stephan, Büllesfeld, Lutz |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1774-024X |
Publisher: |
Europa Digital & Publishing |
Language: |
English |
Submitter: |
Stefan Stortecky |
Date Deposited: |
24 Feb 2014 08:43 |
Last Modified: |
20 Feb 2024 14:17 |
PubMed ID: |
24273249 |
BORIS DOI: |
10.7892/boris.41943 |
URI: |
https://boris.unibe.ch/id/eprint/41943 |