Benefit of pulmonary vein isolation guided by loss of pace capture on the ablation line: results from a prospective 2-center randomized trial.

Steven, Daniel; Sultan, Arian; Reddy, Vivek; Luker, Jakob; Altenburg, Manuel; Hoffmann, Boris; Rostock, Thomas; Servatius, Helge; Stevenson, William G; Willems, Stephan; Michaud, Gregory F (2013). Benefit of pulmonary vein isolation guided by loss of pace capture on the ablation line: results from a prospective 2-center randomized trial. Journal of the American College of Cardiology, 62(1), pp. 44-50. Elsevier 10.1016/j.jacc.2013.03.059

Full text not available from this repository.

OBJECTIVES

This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation.

BACKGROUND

AF/AT recurrence is common after pulmonary vein isolation (PVI).

METHODS

We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs.

RESULTS

Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred.

CONCLUSIONS

The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Servatius, Helge Simon (A)

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0735-1097

Publisher:

Elsevier

Language:

English

Submitter:

Helge Simon Servatius

Date Deposited:

25 Feb 2014 09:52

Last Modified:

29 Mar 2023 23:33

Publisher DOI:

10.1016/j.jacc.2013.03.059

PubMed ID:

23644091