Hearing performance with 2 different high-power sound processors for osseointegrated auditory implants

Kurz, Anja; Caversaccio, Marco; Kompis, Martin (2013). Hearing performance with 2 different high-power sound processors for osseointegrated auditory implants. Otology & neurotology, 34(4), pp. 604-610. Lippincott Williams & Wilkins 10.1097/MAO.0b013e31828864c5

Full text not available from this repository. (Request a copy)

OBJECTIVE

To compare speech understanding of the BAHA BP110 and BAHA Intenso sound processors.

STUDY DESIGN

Prospective experimental study.

SETTING

Tertiary referral center.

PATIENTS

Twenty experienced user of osseointegrated auditory implants with conductive or mixed hearing loss.

INTERVENTIONS

In a first session, half of the participants were fitted with an Intenso, the other half with a BP110. After 1 month of use, aided speech understanding in quiet and in noise was measured, and the other test processor was fitted. One month later, speech understanding with the second sound processor was assessed.

MAIN OUTCOME MEASURES

Speech understanding in quiet and in noise, with noise arriving either from the front, the rear, or the side of the user with the osseointegrated bone conductor.

RESULTS

Significant improvements were found for both processors for speech understanding in quiet (+9.6 to +34.8 percent points; p = 0.02 to 0.001) and in noise (+6.2 to +13.8 dB, p < 0.001). No significant differences were found between the 2 devices for speech in quiet. For noise from the rear, subjects were able to understand speech at signal-to-noise ratios which were lower (less favorable) by -5.1 dB (p < 0.001) when compared with the Intenso.

CONCLUSION

Speech understanding is substantially improved by both devices, with no significant differences between the sound processors in quiet. In noise, speech understanding is significantly better with the BP110 when compared to the Intenso for noise from the rear.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Head Organs and Neurology (DKNS) > Clinic of Ear, Nose and Throat Disorders (ENT)

UniBE Contributor:

Kurz, Anja, Caversaccio, Marco, Kompis, Martin

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1531-7129

Publisher:

Lippincott Williams & Wilkins

Language:

English

Submitter:

Lilian Tschan

Date Deposited:

07 Mar 2014 09:52

Last Modified:

05 Dec 2022 14:29

Publisher DOI:

10.1097/MAO.0b013e31828864c5

PubMed ID:

23652327

URI:

https://boris.unibe.ch/id/eprint/43438

Actions (login required)

Edit item Edit item
Provide Feedback