Reproducibility of peripheral arterial tonometry measurements in male cardiovascular patients

Nil, Markus; Schäfer, Daniela; Radtke, Thomas; Saner, Hugo; Wilhelm, Matthias; Eser, Prisca (2014). Reproducibility of peripheral arterial tonometry measurements in male cardiovascular patients. European journal of clinical investigation EJCI, 44(11), pp. 1065-1071. Wiley-Blackwell 10.1111/eci.12341

[img] Text
eci12341.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (112kB) | Request a copy

BACKGROUND

Assessment of endothelial function of the microvasculature by peripheral arterial tonometry (EndoPAT(®)) has gained increasing popularity in patients with cardiovascular risk factors. Only limited knowledge about its reproducibility in patients with coronary artery disease (CAD) is available. We therefore aimed to quantify reproducibility of EndoPAT(®) parameters in patients with stable CAD.

DESIGN

EndoPAT(®) measurements were performed repeatedly in 78 male patients (age 66 ± 8 years) with CAD on stable medication. We calculated overall mean, standard deviation (SD), coefficient of variation (CV) and intraclass correlation coefficient (ICC) of the following parameters: reactive hyperemic index (RHI), PAT ratio of the postocclusion period 90-150 s as used for calculation of the RHI (PAT ratio90-150 s) and 90-120 s (PAT ratio90-120 s) as used for the often employed Framingham RHI (F-RHI), as well as PAT ratio of the peak hyperemic response (PAT ratiopeak response). Additionally, least significant changes (LSC) for individual subjects and minimum sample sizes for parallel and cross-over design studies were calculated.

RESULTS

Mean RHI was 1·84 (SD 0·36). For RHI, PAT ratio90-150 s , PAT ratio90-120 s , and PAT ratiopeak response the CVs were 17·0%, 25·4%, 26·1%, and 25·0%, respectively. The ICCs were 0·45, 0·49, 0·48 and 0·51, respectively, and LSC for RHI was 47·2%.

CONCLUSIONS

CV of RHI in our population was moderate; however, we consider this precision insufficient to monitor changes in individual patients, as they would need to exceed 47% to show a significant change. Further, the poor ICCs reflect the difficulty of detecting treatment effects in homogenous populations, such as patients with stable CAD.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

Graduate School:

Graduate School for Health Sciences (GHS)

UniBE Contributor:

Schäfer, Daniela, Radtke, Thomas, Saner, Hugo Ernst, Wilhelm, Matthias, Eser, Prisca Christina

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1365-2362

Publisher:

Wiley-Blackwell

Language:

English

Submitter:

David Herzig

Date Deposited:

23 Jan 2015 16:02

Last Modified:

02 Mar 2023 23:25

Publisher DOI:

10.1111/eci.12341

PubMed ID:

25252103

Uncontrolled Keywords:

Endothelial function peripheral arterial tonometry precision reactive hyperemic index reproducibility

BORIS DOI:

10.7892/boris.61870

URI: