Circumferential distribution of the neointima at six-month and two-year follow-up after a bioresorbable vascular scaffold implantation: a substudy of the ABSORB Cohort B Clinical Trial

Bourantas, Christos V; Farooq, Vasim; Zhang, Yaojun; Muramatsu, Takashi; Gogas, Bill D; Thuesen, Leif; McClean, Dougal; Chevalier, Bernard; Windecker, Stephan; Koolen, Jacques; Ormiston, John; Whitbourn, Robert; Dorange, Cecile; Rapoza, Richard; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Serruys, Patrick W (2015). Circumferential distribution of the neointima at six-month and two-year follow-up after a bioresorbable vascular scaffold implantation: a substudy of the ABSORB Cohort B Clinical Trial. EuroIntervention, 10(11), pp. 1299-1306. Europa Digital & Publishing 10.4244/EIJY14M04_11

Full text not available from this repository. (Request a copy)

Aims: To investigate the extent and the circumferential distribution of the neointima tissue developed following an Absorb bioresorbable vascular scaffold (BVS) implantation. Methods and results: Twenty-three patients who were treated with the Absorb BVS and had optical coherence tomographic examination after scaffold implantation, at six-month and at two-year follow-up, were included in the current analysis. The lumen and the scaffold borders were detected and the circumferential thickness of the neointima was measured at one degree intervals. The symmetry of the neointima was defined as: minimum/maximum thickness. The lumen area was decreased at six months compared to baseline but it did not change between six-month and two-year follow-up (baseline: 7.49 [6.13-8.00] mm2, six months: 6.31 (4.75-7.06) mm2, two years: 6.01 [4.67-7.11] mm2, p=0.373). However, the mean neointima thickness (six months: 189 [173-229] μm, two years: 258 [222-283] μm, p<0.0001) and the symmetry index of the neointima (six months: 0.06 [0.02-0.09], two years: 0.27 [0.24-0.36], p<0.0001) were increased at two years. Full circumferential coverage of the vessel wall by neointima tissue was seen in 91% of the studied frames at two years. Conclusions: This study demonstrates that after an Absorb BVS implantation neointima tissue develops that covers almost the whole circumference of the vessel wall. In contrast to the metallic stents, the neointima tissue does not compromise the luminal dimensions. Further research is required to evaluate the neointimal characteristics and assess the potential value of the device in passivating high-risk plaques.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Windecker, Stephan

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1774-024X

Publisher:

Europa Digital & Publishing

Language:

English

Submitter:

Judith Liniger

Date Deposited:

09 Feb 2015 14:26

Last Modified:

05 Dec 2022 14:39

Publisher DOI:

10.4244/EIJY14M04_11

PubMed ID:

24769420

URI:

https://boris.unibe.ch/id/eprint/62129

Actions (login required)

Edit item Edit item
Provide Feedback