Effectiveness of fluorescence-based methods to detect in situ demineralization and remineralization on smooth surfaces.

Moriyama, C M; Rodrigues, J A; Lussi, Adrian; Diniz, M B (2014). Effectiveness of fluorescence-based methods to detect in situ demineralization and remineralization on smooth surfaces. Caries research, 48(6), pp. 507-514. Karger 10.1159/000363074

[img]
Preview
Text
Effectiveness of Fluorescence-Based.pdf - Published Version
Available under License Publisher holds Copyright.

Download (163kB) | Preview

This study aimed to evaluate the effectiveness of fluorescence-based methods (DIAGNOdent, LF; DIAGNOdent pen, LFpen, and VistaProof fluorescence camera, FC) in detecting demineralization and remineralization on smooth surfaces in situ. Ten volunteers wore acrylic palatal appliances, each containing 6 enamel blocks that were demineralized for 14 days by exposure to a 20% sucrose solution and 3 of them were remineralized for 7 days with fluoride dentifrice. Sixty enamel blocks were evaluated at baseline, after demineralization and 30 blocks after remineralization by two examiners using LF, LFpen and FC. They were submitted to surface microhardness (SMH) and cross-sectional microhardness analysis. The integrated loss of surface hardness (ΔKHN) was calculated. The intraclass correlation coefficient for interexaminer reproducibility ranged from 0.21 (FC) to 0.86 (LFpen). SMH, LF and LFpen values presented significant differences among the three phases. However, FC fluorescence values showed no significant differences between the demineralization and remineralization phases. Fluorescence values for baseline, demineralized and remineralized enamel were, respectively, 5.4 ± 1.0, 9.2 ± 2.2 and 7.0 ± 1.5 for LF; 10.5 ± 2.0, 15.0 ± 3.2 and 12.5 ± 2.9 for LFpen, and 1.0 ± 0.0, 1.0 ± 0.1 and 1.0 ± 0.1 for FC. SMH and ΔKHN showed significant differences between demineralization and remineralization phases. There was a negative and significant correlation between SMH and LF and LFpen in the remineralization phase. In conclusion, LF and LFpen devices were effective in detecting demineralization and remineralization on smooth surfaces provoked in situ.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry

UniBE Contributor:

Lussi, Adrian

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0008-6568

Publisher:

Karger

Language:

English

Submitter:

Eveline Carmen Schuler

Date Deposited:

29 Jan 2015 09:52

Last Modified:

25 May 2023 08:55

Publisher DOI:

10.1159/000363074

PubMed ID:

24902775

Uncontrolled Keywords:

Caries detection, Demineralization, Dental caries, Laser fluorescence, Remineralization

BORIS DOI:

10.7892/boris.62231

URI:

https://boris.unibe.ch/id/eprint/62231

Actions (login required)

Edit item Edit item
Provide Feedback