Noninvasive pressure difference mapping derived from 4D flow MRI in patients with unrepaired and repaired aortic coarctation.

Rengier, Fabian; Delles, Michael; Eichhorn, Joachim; Azad, Yoo-Jin; von Tengg-Kobligk, Hendrik; Ley-Zaporozhan, Julia; Dillmann, Rüdiger; Kauczor, Hans-Ulrich; Unterhinninghofen, Roland; Ley, Sebastian (2014). Noninvasive pressure difference mapping derived from 4D flow MRI in patients with unrepaired and repaired aortic coarctation. Cardiovascular diagnosis and therapy, 4(2), pp. 97-103. AME Publishing Company 10.3978/j.issn.2223-3652.2014.03.03

[img] Text
cdt-04-02-097.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

PURPOSE

To develop a method for computing and visualizing pressure differences derived from time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and to compare pressure difference maps of patients with unrepaired and repaired aortic coarctation to young healthy volunteers.

METHODS

4D flow MRI data of four patients with aortic coarctation either before or after repair (mean age 17 years, age range 3-28, one female, three males) and four young healthy volunteers without history of cardiovascular disease (mean age 24 years, age range 20-27, one female, three males) was acquired using a 1.5-T clinical MR scanner. Image analysis was performed with in-house developed image processing software. Relative pressures were computed based on the Navier-Stokes equation.

RESULTS

A standardized method for intuitive visualization of pressure difference maps was developed and successfully applied to all included patients and volunteers. Young healthy volunteers exhibited smooth and regular distribution of relative pressures in the thoracic aorta at mid systole with very similar distribution in all analyzed volunteers. Patients demonstrated disturbed pressures compared to volunteers. Changes included a pressure drop at the aortic isthmus in all patients, increased relative pressures in the aortic arch in patients with residual narrowing after repair, and increased relative pressures in the descending aorta in a patient after patch aortoplasty.

CONCLUSIONS

Pressure difference maps derived from 4D flow MRI can depict alterations of spatial pressure distribution in patients with repaired and unrepaired aortic coarctation. The technique might allow identifying pathophysiological conditions underlying complications after aortic coarctation repair.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology

UniBE Contributor:

von Tengg-Kobligk, Hendrik

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2223-3652

Publisher:

AME Publishing Company

Language:

English

Submitter:

Aisha Stefania Mzinga

Date Deposited:

04 May 2015 10:11

Last Modified:

05 Dec 2022 14:45

Publisher DOI:

10.3978/j.issn.2223-3652.2014.03.03

PubMed ID:

24834408

Uncontrolled Keywords:

Aorta; aortic coarctation; magnetic resonance imaging (MRI); pressure difference mapping; three-dimensional imaging

BORIS DOI:

10.7892/boris.66783

URI:

https://boris.unibe.ch/id/eprint/66783

Actions (login required)

Edit item Edit item
Provide Feedback