Stankovic, Zoran; Fink, Jury; Collins, Jeremy D; Semaan, Edouard; Russe, Maximilian F; Carr, James C; Markl, Michael; Langer, Mathias; Jung, Bernd (2014). K-t GRAPPA-accelerated 4D flow MRI of liver hemodynamics: influence of different acceleration factors on qualitative and quantitative assessment of blood flow. Magnetic resonance materials in physics, biology and medicine MAGMA, 28(2), pp. 149-159. Chapman & Hall 10.1007/s10334-014-0456-1
|
Text
art%3A10.1007%2Fs10334-014-0456-1.pdf - Published Version Available under License Publisher holds Copyright. Download (934kB) | Preview |
OBJECTIVE
We sought to evaluate the feasibility of k-t parallel imaging for accelerated 4D flow MRI in the hepatic vascular system by investigating the impact of different acceleration factors.
MATERIALS AND METHODS
k-t GRAPPA accelerated 4D flow MRI of the liver vasculature was evaluated in 16 healthy volunteers at 3T with acceleration factors R = 3, R = 5, and R = 8 (2.0 × 2.5 × 2.4 mm(3), TR = 82 ms), and R = 5 (TR = 41 ms); GRAPPA R = 2 was used as the reference standard. Qualitative flow analysis included grading of 3D streamlines and time-resolved particle traces. Quantitative evaluation assessed velocities, net flow, and wall shear stress (WSS).
RESULTS
Significant scan time savings were realized for all acceleration factors compared to standard GRAPPA R = 2 (21-71 %) (p < 0.001). Quantification of velocities and net flow offered similar results between k-t GRAPPA R = 3 and R = 5 compared to standard GRAPPA R = 2. Significantly increased leakage artifacts and noise were seen between standard GRAPPA R = 2 and k-t GRAPPA R = 8 (p < 0.001) with significant underestimation of peak velocities and WSS of up to 31 % in the hepatic arterial system (p <0.05). WSS was significantly underestimated up to 13 % in all vessels of the portal venous system for k-t GRAPPA R = 5, while significantly higher values were observed for the same acceleration with higher temporal resolution in two veins (p < 0.05).
CONCLUSION
k-t acceleration of 4D flow MRI is feasible for liver hemodynamic assessment with acceleration factors R = 3 and R = 5 resulting in a scan time reduction of at least 40 % with similar quantitation of liver hemodynamics compared with GRAPPA R = 2.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology 04 Faculty of Medicine > Faculty Institutions > Teaching Staff, Faculty of Medicine |
UniBE Contributor: |
Jung, Bernd |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
0968-5243 |
Publisher: |
Chapman & Hall |
Language: |
English |
Submitter: |
Aisha Stefania Mzinga |
Date Deposited: |
01 May 2015 15:21 |
Last Modified: |
05 Dec 2022 14:45 |
Publisher DOI: |
10.1007/s10334-014-0456-1 |
PubMed ID: |
25099493 |
BORIS DOI: |
10.7892/boris.66862 |
URI: |
https://boris.unibe.ch/id/eprint/66862 |