Franzone, Anna; Pilgrim, Thomas; Heg, Dik; Roffi, Marco; Tüller, David; Vuilliomenet, André; Muller, Olivier; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Räber, Lorenz; Stortecky, Stefan; Wenaweser, Peter Martin; Jüni, Peter; Windecker, Stephan (2015). Clinical Outcomes According to Diabetic Status in Patients Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents: Prespecified Subgroup Analysis of the BIOSCIENCE Trial. Circulation: Cardiovascular interventions, 8(6), e002319. Lippincott Williams & Wilkins 10.1161/CIRCINTERVENTIONS.114.002319

[img] Text
Franzone CircCardiovascInterv 2015.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (2MB) | Request a copy

BACKGROUND

Ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES) proved noninferior to durable polymer everolimus-eluting stents (DP-EES) for a composite clinical end point in a population with minimal exclusion criteria. We performed a prespecified subgroup analysis of the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation (BIOSCIENCE) trial to compare the performance of BP-SES and DP-EES in patients with diabetes mellitus.

METHODS AND RESULTS

BIOSCIENCE trial was an investigator-initiated, single-blind, multicentre, randomized, noninferiority trial comparing BP-SES versus DP-EES. The primary end point, target lesion failure, was a composite of cardiac death, target-vessel myocardial infarction, and clinically indicated target lesion revascularization within 12 months. Among a total of 2119 patients enrolled between February 2012 and May 2013, 486 (22.9%) had diabetes mellitus. Overall diabetic patients experienced a significantly higher risk of target lesion failure compared with patients without diabetes mellitus (10.1% versus 5.7%; hazard ratio [HR], 1.80; 95% confidence interval [CI], 1.27-2.56; P=0.001). At 1 year, there were no differences between BP-SES versus DP-EES in terms of the primary end point in both diabetic (10.9% versus 9.3%; HR, 1.19; 95% CI, 0.67-2.10; P=0.56) and nondiabetic patients (5.3% versus 6.0%; HR, 0.88; 95% CI, 0.58-1.33; P=0.55). Similarly, no significant differences in the risk of definite or probable stent thrombosis were recorded according to treatment arm in both study groups (4.0% versus 3.1%; HR, 1.30; 95% CI, 0.49-3.41; P=0.60 for diabetic patients and 2.4% versus 3.4%; HR, 0.70; 95% CI, 0.39-1.25; P=0.23, in nondiabetics).

CONCLUSIONS

In the prespecified subgroup analysis of the BIOSCIENCE trial, clinical outcomes among diabetic patients treated with BP-SES or DP-EES were comparable at 1 year.

CLINICAL TRIAL REGISTRATION

URL: http://www.clinicaltrials.gov. Unique identifier: NCT01443104.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Kardiologie
04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Kardiologie

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology
04 Faculty of Medicine > Pre-clinic Human Medicine > Institute of Social and Preventive Medicine (ISPM)
04 Faculty of Medicine > Pre-clinic Human Medicine > Department of Clinical Research (DCR)

UniBE Contributor:

Franzone, Anna, Pilgrim, Thomas, Heg, Dierik Hans, Räber, Lorenz, Stortecky, Stefan, Wenaweser, Peter Martin, Jüni, Peter, Windecker, Stephan

Subjects:

600 Technology > 610 Medicine & health
300 Social sciences, sociology & anthropology > 360 Social problems & social services

ISSN:

1941-7632

Publisher:

Lippincott Williams & Wilkins

Language:

English

Submitter:

Doris Kopp Heim

Date Deposited:

11 Jun 2015 16:18

Last Modified:

20 Feb 2024 14:17

Publisher DOI:

10.1161/CIRCINTERVENTIONS.114.002319

PubMed ID:

26043895

Uncontrolled Keywords:

biodegradable polymer sirolimus-eluting stents; diabetes mellitus; durable polymer everolimus-eluting stents

BORIS DOI:

10.7892/boris.69475

URI:

https://boris.unibe.ch/id/eprint/69475

Actions (login required)

Edit item Edit item
Provide Feedback