Schymik, Gerhard; Lefèvre, Thierry; Bartorelli, Antonio L; Rubino, Paolo; Treede, Hendrik; Walther, Thomas; Baumgartner, Helmut; Windecker, Stephan; Wendler, Olaf; Urban, Philip; Mandinov, Lazar; Thomas, Martyn; Vahanian, Alec (2015). European experience with the second-generation Edwards SAPIEN XT transcatheter heart valve in patients with severe aortic stenosis: 1-year outcomes from the SOURCE XT Registry. JACC. Cardiovascular Interventions, 8(5), pp. 657-669. Elsevier 10.1016/j.jcin.2014.10.026

[img] Text
1-s2.0-S193687981500117X-main.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB)

OBJECTIVES

The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting.

BACKGROUND

Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath.

METHODS

The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure.

RESULTS

The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality.

CONCLUSIONS

The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Windecker, Stephan

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1876-7605

Publisher:

Elsevier

Language:

English

Submitter:

Judith Liniger

Date Deposited:

01 Mar 2016 14:35

Last Modified:

05 Dec 2022 14:51

Publisher DOI:

10.1016/j.jcin.2014.10.026

PubMed ID:

25946437

Uncontrolled Keywords:

aortic valve stenosis; minimally invasive; transapical; transcatheter; transfemoral

BORIS DOI:

10.7892/boris.75929

URI:

https://boris.unibe.ch/id/eprint/75929

Actions (login required)

Edit item Edit item
Provide Feedback