Klinke, Glynis; Rohrbach, Marianne; Giugliani, Roberto; Burda, Patricie; Baumgartner, Matthias R; Tran, Christel; Gautschi, Matthias; Mathis, Déborah; Hersberger, Martin (2015). LC-MS/MS based assay and reference intervals in children and adolescents for oxysterols elevated in Niemann-Pick diseases. Clinical biochemistry, 48(9), pp. 596-602. Elsevier 10.1016/j.clinbiochem.2015.03.007

[img] Text
1-s2.0-S016882271500042X-main.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (477kB) | Request a copy

BACKGROUND

Niemann-Pick type C (NP-C) is a rare progressive neurodegenerative lipid storage disorder with heterogeneous clinical presentation and challenging diagnostic procedures. Recently oxysterols have been reported to be specific biomarkers for NP-C but knowledge on the intra-individual variation and on reference intervals in children and adolescents are lacking.

METHODS

We established a LC-MS/MS assay to measure Cholestane-3β, 5α, 6β-triol (C-triol) and 7-Ketocholesterol (7-KC) following Steglich esterification. To assess reference intervals and intra-individual variation we determined oxysterols in 148 children and adolescents from 0 to 18 years and repeat measurements in 19 of them.

RESULTS

The reported method is linear (r>0.99), sensitive (detection limit of 0.03 ng/mL [0.07 nM] for C-triol, and 0.54 ng/mL [1.35 nM] for 7-KC) and precise, with an intra-day imprecision of 4.8% and 4.1%, and an inter-day imprecision of 7.0% and 11.0% for C-triol (28 ng/ml, 67 nM) and 7-KC (32 ng/ml, 80 nM), respectively. Recoveries for 7-KC and C-triol range between 93% and 107%. The upper reference limit obtained for C-triol is 40.4 ng/mL (95% CI: 26.4-61.7 ng/mL, 96.0 nM, 95% CI: 62.8-146.7 nM) and 75.0 ng/mL for 7-KC (95% CI: 55.5-102.5 ng/mL, 187.2 nM, 95% CI: 138.53-255.8 nM), with no age or gender dependency. Both oxysterols have a broad intra-individual variation of 46%±23% for C-triol and 52%±29% for 7-KC. Nevertheless, all Niemann-Pick patients showed increased C-triol levels including Niemann-Pick type A and B patients.

CONCLUSIONS

The LC-MS/MS assay is a robust assay to quantify C-triol and 7-KC in plasma with well documented reference intervals in children and adolescents to screen for NP-C in the pediatric population. In addition our results suggest that especially the C-triol is a biomarker for all three Niemann-Pick diseases.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > Unit Childrens Hospital > Forschungsgruppe Endokrinologie / Diabetologie / Metabolik (Pädiatrie)
04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Institute of Clinical Chemistry
04 Faculty of Medicine > Department of Gynaecology, Paediatrics and Endocrinology (DFKE) > Clinic of Paediatric Medicine

UniBE Contributor:

Gautschi, Matthias

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0009-9120

Publisher:

Elsevier

Language:

English

Submitter:

Anette van Dorland

Date Deposited:

15 Mar 2016 13:49

Last Modified:

05 Dec 2022 14:52

Publisher DOI:

10.1016/j.clinbiochem.2015.03.007

PubMed ID:

25819840

Uncontrolled Keywords:

Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS); Niemann–Pick; Oxysterols; Reference intervals; Steglich esterification

BORIS DOI:

10.7892/boris.76942

URI:

https://boris.unibe.ch/id/eprint/76942

Actions (login required)

Edit item Edit item
Provide Feedback