Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F (2015). Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema? Annals of nuclear medicine, 29(6), pp. 528-534. Springer 10.1007/s12149-015-0976-4

[img]
Preview
Text
Froeling2015_Article_VentilationPerfusionSPECTOrSPE.pdf - Published Version
Available under License Publisher holds Copyright.

Download (830kB) | Preview

PURPOSE

To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema.

MATERIALS AND METHODS

Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test.

RESULTS

Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images.

CONCLUSION

AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology

UniBE Contributor:

Maurer, Martin

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1864-6433

Publisher:

Springer

Language:

English

Submitter:

Aisha Stefania Mzinga

Date Deposited:

17 Mar 2016 10:46

Last Modified:

05 Dec 2022 14:52

Publisher DOI:

10.1007/s12149-015-0976-4

PubMed ID:

25939639

BORIS DOI:

10.48350/77211

URI:

https://boris.unibe.ch/id/eprint/77211

Actions (login required)

Edit item Edit item
Provide Feedback