Homeopathic Preparations of Quartz, Sulfur and Copper Sulfate Assessed by UV-Spectroscopy

Wolf, Ursula; Wolf, Martin; Heusser, Peter; Thurneysen, André; Baumgartner, Stephan (2011). Homeopathic Preparations of Quartz, Sulfur and Copper Sulfate Assessed by UV-Spectroscopy. Evidence-based complementary and alternative medicine eCAM, 2011, p. 692798. New York, N.Y.: Hindawi 10.1093/ecam/nep036

[img]
Preview
Text
692798.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

Homeopathic preparations are used in homeopathy and anthroposophic medicine. Although there is evidence of effectiveness in several clinical studies, including double-blinded randomized controlled trials, their nature and mode of action could not be explained with current scientific approaches yet. Several physical methods have already been applied to investigate homeopathic preparations but it is yet unclear which methods are best suited to identify characteristic physicochemical properties of homeopathic preparations. The aim of this study was to investigate homeopathic preparations with UV-spectroscopy. In a blinded, randomized, controlled experiment homeopathic preparations of copper sulfate (CuSO(4); 11c-30c), quartz (SiO(2); 10c-30c, i.e., centesimal dilution steps) and sulfur (S; 11×-30×, i.e., decimal dilution steps) and controls (one-time succussed diluent) were investigated using UV-spectroscopy and tested for contamination by inductively coupled plasma mass spectrometry (ICP-MS). The UV transmission for homeopathic preparations of CuSO(4) preparations was significantly lower than in controls. The transmission seemed to be also lower for both SiO(2) and S, but not significant. The mean effect size (95% confidence interval) was similar for the homeopathic preparations: CuSO(4) (pooled data) 0.0544% (0.0260-0.0827%), SiO(2) 0.0323% (-0.0064% to 0.0710%) and S 0.0281% (-0.0520% to 0.1082%). UV transmission values of homeopathic preparations had a significantly higher variability compared to controls. In none of the samples the concentration of any element analyzed by ICP-MS exceeded 100 ppb. Lower transmission of UV light may indicate that homeopathic preparations are less structured or more dynamic than their succussed pure solvent.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Medical Education > Institute of Complementary and Integrative Medicine (IKIM)

UniBE Contributor:

Wolf, Ursula, Heusser, Peter, Thurneysen, André, Baumgartner, Stephan

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1741-427X

Publisher:

Hindawi

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 14:23

Last Modified:

05 Dec 2022 14:06

Publisher DOI:

10.1093/ecam/nep036

PubMed ID:

19474239

Web of Science ID:

000293528000001

BORIS DOI:

10.7892/boris.8030

URI:

https://boris.unibe.ch/id/eprint/8030 (FactScience: 213450)

Actions (login required)

Edit item Edit item
Provide Feedback