Creatinine in urine - a method comparison.

Luginbühl, Marc; Weinmann, Wolfgang (2017). Creatinine in urine - a method comparison. Drug testing and analysis, 9(10), pp. 1537-1541. Wiley 10.1002/dta.2166

[img]
Preview
Text
Creatinine%20in%20Urine%20_Rev%202%20corr-Chances%20acc.pdf - Accepted Version
Available under License Publisher holds Copyright.

Download (1MB) | Preview
[img] Text
Luginb-hl_et_al-2017-Drug_Testing_and_Analysis.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (325kB)

Drug screening in urine is widely applied in forensic toxicology. Contrary to blood analysis, excessive or reduced fluid intake can substantially alter the concentration of substances in urine. As a standard to detect urinary dilution, creatinine concentrations are analyzed. A sample with a concentration below 20 mg/dL is generally defined as too diluted to provide a valid result in abstinence control samples. This work investigates the potential of three different methods for the determination of creatinine concentrations in urine samples: A ZIC-HILIC based LC-MS/MS method, a spectrophotometric method on an AU 480 chemistry system, and a portable, immunoassay based point-of-care testing device was compared by measuring 200 urine samples. When comparing the two laboratory methods, LC-MS/MS and spectrophotometry, a mean difference of 3.7 ± 14 mg/dL was found, indicating that the spectrophotometric method is slightly overestimating the creatinine concentration. When comparing the LC-MS/MS method with the point-of-care testing device, a mean concentration difference within the calibration range for POCT (>20 mg/dL (excluding 16 samples) and <500 mg/dL (excluding 4 samples)) of 21 ± 37 mg/dL was found, indicating that the point-of-care testing device overestimates the measured creatinine concentration. A point-of-care testing device as used during this study can provide valuable information for on-site analysis. However, reported concentrations above 500 mg/dL should be further evaluated e.g. by dilution of the sample.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Service Sector > Institute of Legal Medicine

UniBE Contributor:

Weinmann, Wolfgang

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1942-7603

Publisher:

Wiley

Language:

English

Submitter:

Antoinette Angehrn

Date Deposited:

17 Jul 2017 16:43

Last Modified:

05 Dec 2022 15:02

Publisher DOI:

10.1002/dta.2166

PubMed ID:

28102586

Uncontrolled Keywords:

creatinine; drug testing; point-of-care testing; urine analysis; urine manipulation

BORIS DOI:

10.7892/boris.94616

URI:

https://boris.unibe.ch/id/eprint/94616

Actions (login required)

Edit item Edit item
Provide Feedback