Wyler, Florian

Up a level
Export as [feed] RSS
Group by: Date | Item Type | Refereed | No Grouping

Wyler, Florian; Manogaran, Thuvarakha; Monney, Nathalie; Salem, Yasmin; Steinberg, Ruth; Kentgens, Anne-Christianne; Jacobs, Carvern; Chaya, Shaakira; Sena, Carla Rebeca da Silva; Künstle, Noëmi; Gorlanova, Olga; Yammine, Sophie; Gray, Diane M; Frey, Urs; Oestreich, Marc-Alexander; Latzin, Philipp (2024). Optimized algorithm for speed-of-sound-based infant sulfur hexafluoride multiple-breath washout measurements. (In Press). Pediatric pulmonology Wiley 10.1002/ppul.27180

Oestreich, Marc-Alexander; Wyler, Florian; Buess, Christian; Etter, Blaise; Ramsey, Kathryn A; Latzin, Philipp (2024). Signal-correction errors in the EasyOne Pro LAB multiple-breath washout device significantly impact outcomes in children and adults. Journal of applied physiology, 136(3), pp. 460-471. American Physiological Society 10.1152/japplphysiol.00096.2022

Oestreich, Marc-Alexander; Hänni, Robin; Wyler, Florian; Kentgens, Anne-Christianne; Yammine, Sophie; Obrist, Dominik; Latzin, Philipp; Ramsey, Kathryn A (2024). Comparison of functional residual capacity between updated infant SF6 multiple-breath washout setups. Pediatric pulmonology, 59(2), pp. 518-520. Wiley 10.1002/ppul.26770

Oestreich, Marc-Alexander; Doswald, Isabelle; Salem, Yasmin; Künstle, Noëmi; Wyler, Florian; Frauchiger, Bettina S; Kentgens, Anne-Christianne; Latzin, Philipp; Yammine, Sophie (2024). A computerized tool for the systematic visual quality assessment of infant multiple-breath washout measurements. Frontiers in Pediatrics, 12 Frontiers 10.3389/fped.2024.1393291

Kentgens, Anne-Christianne; Pusterla, Orso; Bauman, Grzegorz; Santini, Francesco; Wyler, Florian; Curdy, Marion S; Willers, C Corin; Bieri, Oliver; Latzin, Philipp; Ramsey, Kathryn A (2023). Simultaneous multiple breath washout and oxygen-enhanced magnetic resonance imaging in healthy adults. Respiratory medicine and research, 83(100993), p. 100993. Elsevier 10.1016/j.resmer.2023.100993

Frauchiger, Bettina Sarah; Oestreich, Marc-Alexander; Wyler, Florian; Monney, Nathalie; Willers, Corin; Yammine, Sophie; Latzin, Philipp (2022). Do clinimetric properties of LCI change after correction of signal processing? Pediatric pulmonology, 57(5), pp. 1180-1187. Wiley-Blackwell 10.1002/ppul.25865

Oestreich, Marc-Alexander; Wyler, Florian; Latzin, Philipp; Ramsey, Kathryn A (2022). Impact of Spiroware re-analysis method on multiple-breath washout outcomes in children with cystic fibrosis. Journal of cystic fibrosis, 21(3), e208-e209. Elsevier 10.1016/j.jcf.2022.02.013

Fouzas, Sotirios; Kentgens, Anne-Christianne; Lagiou, Olga; Frauchiger, Bettina Sarah; Wyler, Florian; Theodorakopoulos, Ilias; Yammine, Sophie; Latzin, Philipp (2022). Novel volumetric capnography indices measure ventilation inhomogeneity in cystic fibrosis. ERJ Open Research, 8(1) 10.1183/23120541.00440-2021

Oestreich, Marc-Alexander; Wyler, Florian; Frauchiger, Bettina S; Latzin, Philipp; Ramsey, Kathryn A (2022). Breath detection algorithms affect multiple-breath washout outcomes in pre-school and school age children. PLoS ONE, 17(10), e0275866. Public Library of Science 10.1371/journal.pone.0275866

Valk, Anne; Willers, Corin; Shahim, Kamal; Pusterla, Orso; Bauman, Grzegorz; Sandkühler, Robin; Bieri, Oliver; Wyler, Florian; Latzin, Philipp (2021). Defect distribution index: A novel metric for functional lung MRI in cystic fibrosis. Magnetic resonance in medicine, 86(6), pp. 3224-3235. Wiley-Liss 10.1002/mrm.28947

Wyler, Florian; Oestreich, Marc-Alexander; Frauchiger, Bettina S.; Ramsey, Kathryn A.; Latzin, Philipp (2021). Correction of sensor crosstalk error in Exhalyzer D multiple-breath washout device significantly impacts outcomes in children with cystic fibrosis. Journal of applied physiology, 131(3), pp. 1148-1156. American Physiological Society 10.1152/japplphysiol.00338.2021

Oestreich, Marc-Alexander; Wyler, Florian; Latzin, Philipp; Ramsey, Kathryn A. (2021). Shedding light into the black box of infant multiple-breath washout. Pediatric pulmonology, 56(8), pp. 2642-2653. Wiley-Blackwell 10.1002/ppul.25464

Wyler, Florian; Oestreich, Marc-Alexander; Frauchiger, Bettina S.; Ramsey, Kathryn; Latzin, Philipp (12 February 2021). Correction of measurement error in a commercial multiple-breath washout device (medRxiv). Cold Spring Harbor Laboratory 10.1101/2021.02.06.21251250