Ozan, Oğuz; Şeker, Emre; Cakmak, Gülce; Guo, Xiaohan; Yilmaz, Burak (2022). Effect of guide sleeve material, region, diameter, and number of times drills were used on the material loss from sleeves and drills used for surgical guides: An in vitro study. The journal of prosthetic dentistry, 128(4), pp. 746-753. Elsevier 10.1016/j.prosdent.2020.12.036
Text
1-s2.0-S0022391321000184-main.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (1MB) |
STATEMENT OF PROBLEM
How material loss from sleeves and drills is affected when different guide sleeve materials and different sizes of implant drills are used for different regions of surgical guides is unclear.
PURPOSE
The purpose of this in vitro study was to compare the amount of material loss from different guide sleeves (zirconia and cobalt-chromium) and drills of different diameters during osteotomy preparation in different regions.
MATERIAL AND METHODS
Three tooth-supported surgical guides with sleeve holes positioned in the first premolar and second molar sites were prepared. Guide sleeves (Ø 2.20 mm, 3.40 mm, and 4.05 mm) were milled from zirconia (n=60) and cobalt-chromium (n=60) blocks. A total of 12 titanium nitride-coated stainless steel twisted drills (n=6 per sleeve material) of different diameters (Ø 2.00, 3.20, 3.85 mm) were used with corresponding sleeves during the drilling. The weight loss from the drills and the volume loss from the guide sleeves after drilling were analyzed by using multiple linear mixed effect models (α=.05).
RESULTS
According to the 4-way ANOVA for volume loss from sleeves, no significant interaction was found among the 4 main effects (number of times a drill was used, region, diameter, and material), but interactions between the number of times a drill was used and diameter (P=.001) and between the number of times the drill was used and material were significant (P<.001). For weight loss from the drills, a significant interaction was detected between the number of times the drill was used and diameter (P=.024).
CONCLUSIONS
Less sleeve material was lost when zirconia sleeves were used. All sleeves had more material loss in the molar region than in the premolar region. The diameter had varying effects on the amount of material loss from drills and sleeves. The sleeve material and the region did not affect the material loss from drills.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine 04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology 04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry 04 Faculty of Medicine > School of Dental Medicine > Restorative Dentistry, Research |
UniBE Contributor: |
Cakmak, Gülce, Yilmaz, Burak |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1097-6841 |
Publisher: |
Elsevier |
Language: |
English |
Submitter: |
Tina Lauper |
Date Deposited: |
28 Jun 2021 14:49 |
Last Modified: |
05 Dec 2022 15:51 |
Publisher DOI: |
10.1016/j.prosdent.2020.12.036 |
PubMed ID: |
33832763 |
BORIS DOI: |
10.48350/156973 |
URI: |
https://boris.unibe.ch/id/eprint/156973 |