Prosthetic complications with monolithic or micro-veneered implant-supported zirconia single-unit, multiple-unit, and complete-arch prostheses on titanium base abutments: A single center retrospective study with mean follow-up period of 72.35 months.

Saponaro, Paola C; Karasan, Duygu; Donmez, Mustafa Borga; Johnston, William Michael; Yilmaz, Burak (2023). Prosthetic complications with monolithic or micro-veneered implant-supported zirconia single-unit, multiple-unit, and complete-arch prostheses on titanium base abutments: A single center retrospective study with mean follow-up period of 72.35 months. Clinical implant dentistry and related research, 25(1), pp. 99-106. Wiley 10.1111/cid.13149

[img] Text
Clin_Implant_Dent_Rel_Res_-_2022_-_Saponaro_-_Prosthetic_complications_with_monolithic_or_micro_veneered_implant_supported.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (893kB)

BACKGROUND

The influence of prosthetic design on prosthetic complications when monolithic or micro-veneered zirconia prostheses are supported with titanium base (ti-base) abutments is not well-known.

PURPOSE

The purpose of this single center, retrospective study was to assess the prevalence of prosthetic complications with monolithic or micro-veneered single-unit, multi-unit, and complete-arch zirconia prostheses supported with ti-base abutments (implant level or multi-unit abutment level).

MATERIAL AND METHODS

This study retrospectively evaluated the electronic health record (EHR) of participants who received either monolithic or micro-veneered implant-supported single-unit, multi-unit, and/or complete-arch prostheses supported by ti-base or zirconia-ti-base hybrid abutments delivered between the years 2010 and 2021. Data were analyzed by using logistic regression and Exact Mantel-Haenszel chi-square test (α = 0.05) to assess the clinical performance of prostheses and complications including crown decementation, feldspathic porcelain chipping, prosthesis fracture, zirconia-ti-base hybrid abutment decementation, abutment screw loosening, screw fracture, abutment fracture, implant loss, and prosthesis remake.

RESULTS

The study included 94 participants (50 female, 44 male) with a mean age of 59.5 years (range: 24-101 years of age). The retrospective EHR evaluation yielded 82 single-unit, 51 multi-unit, and 20 complete-arch prostheses on 325 implants. Among 153 prostheses delivered, 108 were micro-veneered (47 single-unit, 41 multi-unit, and 20 complete-arch prostheses) and 45 were monolithic. The average duration was 72.35 months (6.02 years) with a follow-up period of 5-132 months. From the time of insertion to the time of EHR review, of 153 prostheses, 78.43% did not exhibit any prosthetic complication. However, 33 prostheses (21.57%) from 29 participants (30.85%) had at least one prosthetic complication. Only four patients (4.25%) experienced two or more prosthetic complications. Prosthetic design affected the probability of having a complication (p = 0.005); complete-arch prostheses had higher probability (p ≤ 0.028). Single-unit prostheses had lower probability of complication than multi-unit prostheses (p = 0.005). The most commonly observed complication was fracture of veneering material (5.88%) followed by prosthetic screw loosening (4.57%) and decementation between the zirconia and the ti-base abutment (2.61%). Micro-veneered complete-arch prostheses had higher probability of having chipping than that of not having (p < 0.001), and other micro-veneered prosthetic designs had similar probability of chipping with that of complete-arch prostheses (p ≥ 0.082). Frequency of chipping was affected by veneering (p < 0.001). Monolithic prostheses had lower probability of chipping than micro-veneered prostheses, regardless of the prosthetic design (p < 0.001).

CONCLUSIONS

The frequency of prosthetic complications varied depending on prosthetic design. Complete-arch prostheses had the highest probability of complications while the single-unit prostheses had the lowest. Micro-veneered prostheses had higher probability for chipping than monolithic prostheses. Probability of chipping was similar for micro-veneered single-unit, multi-unit, and complete-arch zirconia prostheses.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry
04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology
04 Faculty of Medicine > School of Dental Medicine

UniBE Contributor:

Dönmez, Mustafa-Borga, Yilmaz, Burak

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1708-8208

Publisher:

Wiley

Language:

English

Submitter:

Pubmed Import

Date Deposited:

03 Nov 2022 10:54

Last Modified:

08 Feb 2023 00:13

Publisher DOI:

10.1111/cid.13149

PubMed ID:

36321480

Uncontrolled Keywords:

chipping implant-supported monolithic zirconia prosthetic design zirconia-ti-base hybrid abutment