Donmez, Mustafa Borga; Mathey, Ayse; Gäumann, Fabio; Mathey, Amber; Yilmaz, Burak; Abou-Ayash, Samir (2023). Effect of intraoral scanner and fixed partial denture situation on the scan accuracy of multiple implants: An in vitro study. Clinical implant dentistry and related research, 25(3), pp. 502-510. Wiley 10.1111/cid.13190
|
Text
Clin_Implant_Dent_Rel_Res_-_2023_-_Donmez_-_Effect_of_intraoral_scanner_and_fixed_partial_denture_situation_on_the_scan.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (1MB) | Preview |
BACKGROUND
Accuracy of intraoral implant scans may be affected by the region of the implant and the type of the intraoral scanner (IOSs). However, there is limited knowledge on the scan accuracy of multiple implants placed for an implant-supported fixed partial denture (FPD) in different partially edentulous situations when digitized by using different IOSs.
PURPOSE
To investigate the effect of IOS and FPD situation on the scan accuracy of two implants when partial-arch scans were performed.
MATERIALS AND METHODS
Tissue level implants were placed in 3 maxillary models with implant spaces either at right first premolar and right first molar sites (Model 1, 3-unit FPD), at right canine and right first molar sites (Model 2, 4-unit FPD), or at lateral incisor sites (Model 3, 4-unit FPD). Reference standard tessellation language (STL) files of the models were generated by using an optical scanner (ATOS Capsule 200MV120). Two IOSs (CEREC Primescan [CP] and TRIOS 3 [TR]) were used to perform partial-arch scans (test-scans) of each model (n = 14), which were exported in STL format. A metrology-grade analysis software (GOM Inspect 2018) was used to superimpose test-scan STLs over the reference STL to calculate 3D distance, inter-implant distance, and angular (mesiodistal and buccopalatal) deviations. Trueness and precision analyses were performed by using bootstrap analysis of variance followed by Welch tests with Holm correction (α = 0.05).
RESULTS
Trueness of the scans was affected by IOS and FPD situation when 3D distance deviations were considered, while inter-implant distance, mesiodistal angular, and buccopalatal angular deviations were only affected by the FPD situation (p < 0.001). Scan precision was affected by the interaction between the IOSs and the FPD situation when 3D distance and buccopalatal angular deviations were concerned, while IOSs and FPD situation were effective when all deviations were concerned (p≤ 0.001). When 3D distance deviations were considered, CP scans had higher accuracy TR scans in Models 1 and 3 (p ≤ 0.002), and the Model 1 scans had the highest accuracy (p < 0.001). When inter-implant distance deviations were considered, Model 1 scans had the highest accuracy with CP and higher accuracy than Model 2 when TR was used (p ≤ 0.030). When mesiodistal angular deviations were considered, Model 1 scans had the highest accuracy (p ≤ 0.040). When buccopalatal angular deviations were considered, Model 1 scans had the highest accuracy among models when CP was used (p ≤ 0.020).
CONCLUSIONS
Posterior 3-unit fixed partial denture implant scans, CP scans, and combination of these two factors had accuracy either similar to or better than their tested counterparts.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry 04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology 04 Faculty of Medicine > School of Dental Medicine |
UniBE Contributor: |
Dönmez, Mustafa-Borga, Mathey, Ayse Annette, Yilmaz, Burak |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1708-8208 |
Publisher: |
Wiley |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
13 Feb 2023 13:07 |
Last Modified: |
06 Jun 2023 00:13 |
Publisher DOI: |
10.1111/cid.13190 |
PubMed ID: |
36762495 |
Uncontrolled Keywords: |
fixed partial denture implant intraoral scanner precision trueness |
BORIS DOI: |
10.48350/178624 |
URI: |
https://boris.unibe.ch/id/eprint/178624 |