Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: A systematic review.

Donmez, Mustafa Borga; Gómez-Polo, Miguel; Çakmak, Gülce; Yilmaz, Burak; Revilla-León, Marta (2023). Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: A systematic review. Journal of prosthodontics, 32(S2), pp. 165-180. Wiley 10.1111/jopr.13774

[img] Text
Journal_of_Prosthodontics_-_2023_-_Donmez.pdf - Accepted Version
Restricted to registered users only until 28 September 2024.
Available under License Publisher holds Copyright.

Download (757kB) | Request a copy

PURPOSE

To evaluate the influence of implant scan body (ISB) design (height, diameter, geometry, material, and retention system) on the accuracy of digital implant scans.

MATERIAL AND METHODS

A literature search was completed in 5 databases: PubMed/Medline, Scopus, Embase, World of Science, and Cochrane. A manual search was also conducted. Studies reporting the evaluation of ISB design on the accuracy of digital scans obtained by using IOSs were included. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus. Articles were classified based on the ISB features of height, geometry, material, and retention system.

RESULTS

Twenty articles were included. Among the reviewed studies, 11 investigations analyzed the influence of different ISB geometries, 1 study assessed the impact of ISB diameter, 4 studies investigated the effect of ISB splinting, 2 articles evaluated ISB height, and 2 studies focused on the effect of ISB material on scan accuracy. In addition, 8 studies involved ISBs fabricated with different materials (1- and 2-piece polyetheretherketone and 1-piece titanium ISBs), and all of the reviewed articles tested screw-retained ISBs, except for 3 in vitro studies.

CONCLUSIONS

The findings did not enable concrete conclusions regarding the optimal ISB design, whether there is a relationship between IOS technology and a specific ISB design, or the clinical condition that maximizes intraoral scanning accuracy. Research efforts are needed to identify the optimal ISB design and its possible relationship with the IOS selected for acquiring intraoral digital implant scans. This article is protected by copyright. All rights reserved.

Item Type:

Journal Article (Review Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry
04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology
04 Faculty of Medicine > School of Dental Medicine

UniBE Contributor:

Dönmez, Mustafa-Borga, Cakmak, Gülce, Yilmaz, Burak

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1532-849X

Publisher:

Wiley

Language:

English

Submitter:

Pubmed Import

Date Deposited:

02 Oct 2023 15:01

Last Modified:

03 Dec 2023 00:16

Publisher DOI:

10.1111/jopr.13774

PubMed ID:

37771200

Uncontrolled Keywords:

accuracy digital impression implant scan body prosthodontics