Turksayar, Almira Ada Diken; Dönmez, Mustafa Borga (2023). Stress behavior of an anterior single implant restored with high performance polymer abutments under immediate and delayed loading: A 3D FEA study. Journal of prosthodontics, 32(2), pp. 132-138. Wiley 10.1111/jopr.13598
|
Text
Journal_of_Prosthodontics_-_2022_-_Turksayar_-_Stress_behavior_of_an_anterior_single_implant_restored_with_high_performance.pdf - Accepted Version Available under License Publisher holds Copyright. Download (1MB) | Preview |
PURPOSE
To evaluate the stress generated on peripheral bone, implant, and prosthetic components while using polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) hybrid abutments in two different loading situations with nonlinear 3D finite element analysis.
MATERIALS AND METHODS
Standard tessellation language (STL) files of original components were used for the in-silico modeling of implant, standard titanium abutment, and hybrid abutments (PEEK and PEKK). The implant was placed in the bone block to imitate immediate loading, in which a friction coefficient of 0.3 was set between the bone and the implant interface, or delayed loading, where the bone-implant interface was assumed to be perfect. In all models, both a horizontal force (25.5 N) and a 30-degree oblique force (178 N) were applied to the long axis of the implant to the palatal surface of the restoration. The stress distribution was evaluated.
RESULTS
While more stress was observed in the prosthetic structures in the PEEK and PEKK models, the stresses on the implant and bone were similar in all models, regardless of the loading situation. Under immediate loading, PEEK hybrid abutments caused excessive stress accumulation on the titanium base abutment.
CONCLUSIONS
Even though abutment type did not affect the stresses on peripheral bone, PEEK and PEKK abutments generated greater stresses on the implant and the standard titanium abutment accumulated higher stresses. Oblique forces mostly generated greater stress than horizontal forces. Oblique forces on immediately loaded implant led to stresses higher than the yield strength of a titanium implant when restored with PEEK hybrid abutment. This article is protected by copyright. All rights reserved.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine 04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology |
UniBE Contributor: |
Dönmez, Mustafa-Borga |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1532-849X |
Publisher: |
Wiley |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
26 Aug 2022 10:51 |
Last Modified: |
26 Aug 2023 00:25 |
Publisher DOI: |
10.1111/jopr.13598 |
PubMed ID: |
36007157 |
Uncontrolled Keywords: |
finite element analysis implant abutment polyetheretherketone polyetherketoneketone |
BORIS DOI: |
10.48350/172378 |
URI: |
https://boris.unibe.ch/id/eprint/172378 |