Quirynen, Marc; Al-Nawas, Bilal; Meijer, Henny J A; Razavi, Amir; Reichert, Torsten E; Schimmel, Martin; Storelli, Stefano; Romeo, Eugenio (2015). Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controlled trial. Clinical oral implants research, 26(7), pp. 831-840. Wiley-Blackwell 10.1111/clr.12367
Text
Small-diameter titanium Grade IV.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (337kB) |
OBJECTIVE
The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures.
MATERIALS AND METHODS
This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of loading. Modified plaque and sulcus bleeding indices, radiographic bone level, and implant survival and success were evaluated up to 36 months.
RESULTS
Of 91 treated patients, 75 completed the three-year follow-up. Three implants were lost (two control and one test implant). The survival rates were 98.7% and 97.3%, and the mean marginal bone level change was -0.78 ± 0.75 and -0.60 ± 0.71 mm for TiZr and Ti Grade IV implants. Most patients had a plaque score of 0 or 1 (54% for test and 51.7% for control), and a sulcus bleeding score of 0 (46.1% for test and 44.9% for control). No significant differences were found between the two implant types for bone-level change, soft tissue parameters, survival and success.
CONCLUSIONS
After 36 months, similar outcomes were found between Ti Grade IV and TiZr implants. The results confirm that the results seen at 12 months continue over time.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology |
UniBE Contributor: |
Schimmel, Martin |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
0905-7161 |
Publisher: |
Wiley-Blackwell |
Language: |
English |
Submitter: |
Eveline Carmen Schuler |
Date Deposited: |
21 Apr 2016 14:13 |
Last Modified: |
05 Dec 2022 14:55 |
Publisher DOI: |
10.1111/clr.12367 |
PubMed ID: |
24713048 |
Uncontrolled Keywords: |
edentulous, Roxolid, SLActive surface, Titanium/zirconium |
BORIS DOI: |
10.7892/boris.81297 |
URI: |
https://boris.unibe.ch/id/eprint/81297 |