Donmez, Mustafa Borga; Rizzo Marques, Vinicius; Cakmak, Gülce; Yilmaz, Hakan; Schimmel, Martin; Yilmaz, Burak (2022). Congruence between the meshes of a combined healing abutment-scan body system acquired with four different intraoral scanners and the corresponding library file: an in vitro analysis. Journal of dentistry, 118, p. 103938. Elsevier Science 10.1016/j.jdent.2021.103938

[img]
Preview
Text
1-s2.0-S0300571221003602-main__002_.pdf - Accepted Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND).

Download (1MB) | Preview

OBJECTIVES

To investigate the congruence between the meshes of a combined healing abutment-scan body (CHA-SB) system acquired with four different intraoral scanners and the corresponding library file.

MATERIAL AND METHODS

A CHA-SB was fixed to an implant at the right first molar position in a dentate mandibular model and digitized by using 4 different intraoral scanners (IOSs) [TRIOS 3 (T3), Omnicam (OC), Primescan (PS), and Virtuo Vivo (VV)] (n=8) and an industrial grade optical scanner (ATOS Core 80) (n=1) to generate standard tessellation language (STL) files of the test scans (CHA-SB-STLs) and the master reference model scan (MRM-STL). A reverse engineering software (Studio Geomagic X) was used to superimpose the proprietary library file of the CHASB over the generated STL files. Root mean square (RMS) values representing the deviations between the library file and the superimposed STL files were statistically analyzed by using 1-way ANOVA (α=.05). Qualitative analysis of the deviations was performed by visual inspection.

RESULTS

Differences between the congruence of the library file and the CHA-SB scans among different IOSs were nonsignificant (F=1.619, df= 3, P = .207). The single best result was 29 ±28.9 µm for OC, 30.8 ±29.6 µm for VV, 35.6 ±35.5 µm for T3, and 39.5 ±39.2 µm for PS, which were all above the deviation value of the scan performed by using the industrial-grade scanner (23.2 ±23.2 µm).

CONCLUSION

The dimensional congruence between the library file and the standard tessellation language file of the combined healing abutment-scan body system scans was similar when intraoral scanners with different acquisition technologies were used to scan a model with an implant.

CLINICAL SIGNIFICANCE

Scans of the tested intraoral scanners may result in crowns with similar positional accuracy, given the similarities in congruence of their scans with the library file.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine
04 Faculty of Medicine > School of Dental Medicine > Department of Reconstructive Dentistry and Gerodontology

UniBE Contributor:

Rizzo-Marques, Vinicius, Cakmak, Gülce, Schimmel, Martin, Yilmaz, Burak

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0300-5712

Publisher:

Elsevier Science

Language:

English

Submitter:

Lena Augé

Date Deposited:

13 Jan 2022 13:58

Last Modified:

23 Dec 2022 00:25

Publisher DOI:

10.1016/j.jdent.2021.103938

PubMed ID:

34942277

Uncontrolled Keywords:

accuracy healing abutment-scan body intraoral scanner trueness

BORIS DOI:

10.48350/163257

URI:

https://boris.unibe.ch/id/eprint/163257

Actions (login required)

Edit item Edit item
Provide Feedback