Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests.

Hartnack, Sonja; Nilius, Henning; Jegerlehner, Sabrina; Suter-Riniker, Franziska; Bittel, Pascal; Jent, Philipp; Nagler, Michael (2023). Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests. Diagnostics, 13(18) MDPI 10.3390/diagnostics13182892

[img]
Preview
Text
diagnostics-13-02892-v2.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

BACKGROUND

Currently, assessing the diagnostic performance of new laboratory tests assumes a perfect reference standard, which is rarely the case. Wrong classifications of the true disease status will inevitably lead to biased estimates of sensitivity and specificity.

OBJECTIVES

Using Bayesian' latent class models (BLCMs), an approach that does not assume a perfect reference standard, we re-analyzed data of a large prospective observational study assessing the diagnostic accuracy of an antigen test for the diagnosis of SARS-CoV-2 infection in clinical practice.

METHODS

A cohort of consecutive patients presenting to a COVID-19 testing facility affiliated with a Swiss University Hospital were recruited (n = 1465). Two real-time PCR tests were conducted in parallel with the Roche/SD Biosensor rapid antigen test on nasopharyngeal swabs. A two-test (PCR and antigen test), three-population BLCM was fitted to the frequencies of paired test results.

RESULTS

Based on the BLCM, the sensitivities of the RT-PCR and the Roche/SD Biosensor rapid antigen test were 98.5% [95% CRI 94.8;100] and 82.7% [95% CRI 66.8;100]. The specificities were 97.7% [96.1;99.7] and 99.9% [95% CRI 99.6;100].

CONCLUSIONS

Applying the BLCM, the diagnostic accuracy of RT-PCR was high but not perfect. In contrast to previous results, the sensitivity of the antigen test was higher. Our results suggest that BLCMs are valuable tools for investigating the diagnostic performance of laboratory tests in the absence of perfect reference standard.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Institute of Clinical Chemistry
04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Infectiology
04 Faculty of Medicine > Service Sector > Institute for Infectious Diseases > Clinical Microbiology
04 Faculty of Medicine > Service Sector > Institute for Infectious Diseases
04 Faculty of Medicine > Department of Intensive Care, Emergency Medicine and Anaesthesiology (DINA) > University Emergency Center

UniBE Contributor:

Nilius, Henning Jürgen Jean, Jegerlehner, Sabrina, Suter, Franziska Marta, Bittel, Pascal, Jent, Philipp, Nagler, Michael

Subjects:

600 Technology > 610 Medicine & health
500 Science > 570 Life sciences; biology

ISSN:

2075-4418

Publisher:

MDPI

Language:

English

Submitter:

Pubmed Import

Date Deposited:

02 Oct 2023 13:26

Last Modified:

02 Oct 2023 13:35

Publisher DOI:

10.3390/diagnostics13182892

PubMed ID:

37761259

Uncontrolled Keywords:

BLCM diagnostic accuracy no gold standard models

BORIS DOI:

10.48350/186769

URI:

https://boris.unibe.ch/id/eprint/186769

Actions (login required)

Edit item Edit item
Provide Feedback