Evaluation of the PrioCHECK™ Trichinella AAD kit to detect Trichinella spiralis, T. britovi, and T. pseudospiralis larvae in pork using the automated digestion method Trichomatic-35.

Basso, Walter; Marreros Canales, Nelson Antonio; Hofmann, Larissa; Salvisberg, Christine; Lundström-Stadelmann, Britta; Frey, Caroline F. (2022). Evaluation of the PrioCHECK™ Trichinella AAD kit to detect Trichinella spiralis, T. britovi, and T. pseudospiralis larvae in pork using the automated digestion method Trichomatic-35. Parasitology international, 86, p. 102449. Elsevier 10.1016/j.parint.2021.102449

[img]
Preview
Text
Frey_Caroline_Evaluation_of_the_PrioCheck_Trichinella_AAD_1-s2.0-S1383576921001677-main.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (6MB) | Preview

Trichinellosis is a potentially deadly parasitic zoonosis that is contracted by consuming undercooked infected meat. Reliable detection of infectious Trichinella spp. larvae in meat is therefore pivotal to ensure consumer's safety. The recently authorised PrioCHECK™ Trichinella Alternative Artificial Digestion (AAD) test kit appears promising when used with the standard magnetic stirrer method, but evaluation with other apparatus types is lacking. In this study, the performance of the AAD kit in an adapted Trichomatic-35 (TM35) instrument was evaluated, first, at the Swiss National Reference Laboratory for trichinellosis (NRL); second, in a ring trial involving four Swiss official laboratories. Proficiency pork samples spiked with larvae of Trichinella spiralis, T. britovi, or T. pseudospiralis were tested with the AAD kit and with the reference pepsin-HCl digestion method in TM35 instruments. At the NRL, both methods yielded identical qualitative and similar quantitative results independently of the Trichinella species. In the ring trial, satisfactory results were obtained for 47/50 (94.0%) (AAD) and 62/67 (92.5%) (reference method) of the analysed samples. Technical problems impairing analysis were more frequently observed with the AAD kit (n = 22) than with the reference method (n = 5) and were mainly (16/22) reported by one of the external labs. When no technical issues were recorded, the performance of both methods was comparable, in agreement with the observations at the NRL; however, these results suggest a need for further training with the kit and standardisation of the adapted TM35 instruments.

Item Type:

Journal Article (Original Article)

Division/Institute:

05 Veterinary Medicine > Department of Infectious Diseases and Pathobiology (DIP) > Institute of Parasitology

UniBE Contributor:

Basso, Walter Ubaldo, Marreros Canales, Nelson Antonio, Hofmann, Larissa, Salvisberg, Christine, Lundström Stadelmann, Britta, Frey Marreros Canales, Caroline Franziska

Subjects:

500 Science
500 Science > 570 Life sciences; biology
500 Science > 590 Animals (Zoology)
600 Technology > 610 Medicine & health
600 Technology > 630 Agriculture

ISSN:

1383-5769

Publisher:

Elsevier

Language:

English

Submitter:

Katharina Gerber-Paizs

Date Deposited:

11 Nov 2021 15:51

Last Modified:

02 Mar 2023 23:35

Publisher DOI:

10.1016/j.parint.2021.102449

PubMed ID:

34481946

Uncontrolled Keywords:

Artificial digestion Diagnostic Pepsin Pig Serin-endopeptidase Trichinellosis

BORIS DOI:

10.48350/160684

URI:

https://boris.unibe.ch/id/eprint/160684

Actions (login required)

Edit item Edit item
Provide Feedback