Prenosil, George

Up a level
Export as [feed] RSS
Group by: Date | Item Type | Refereed | No Grouping
Jump to: Yes

Yes

Mercolli, Lorenzo; Zeimpekis, Konstantinos; Prenosil, George A; Sari, Hasan; Rathke, Hendrik G; Rominger, Axel; Shi, Kuangyu (2024). Phantom study for 90Y liver radioembolization dosimetry with a long axial field-of-view PET/CT. Physica medica, 118, p. 103296. Elsevier 10.1016/j.ejmp.2024.103296

Alberts, Ian L; Mercolli, Lorenzo; Pyka, Thomas; Prenosil, George; Shi, Kuangyu; Rominger, Axel; Afshar-Oromieh, Ali (2023). Large language models (LLM) and ChatGPT: what will the impact on nuclear medicine be? European journal of nuclear medicine and molecular imaging, 50(6), pp. 1549-1552. Springer-Verlag 10.1007/s00259-023-06172-w

Zeimpekis, Konstantinos G.; Mercolli, Lorenzo; Conti, Maurizio; Sari, Hasan; Prenosil, George; Shi, Kuangyu; Rominger, Axel (2023). Phantom-based evaluation of yttrium-90 datasets using biograph vision quadra. European journal of nuclear medicine and molecular imaging, 50(4), pp. 1168-1182. Springer 10.1007/s00259-022-06074-3

Sari, Hasan; Teimoorisichani, Mohammadreza; Mingels, Clemens; Alberts, Ian; Panin, Vladimir; Bharkhada, Deepak; Xue, Song; Prenosil, George; Shi, Kuangyu; Conti, Maurizio; Rominger, Axel (2022). Quantitative evaluation of a deep learning-based framework to generate whole-body attenuation maps using LSO background radiation in long axial FOV PET scanners. European journal of nuclear medicine and molecular imaging, 49(13), pp. 4490-4502. Springer 10.1007/s00259-022-05909-3

Guo, Rui; Xue, Song; Hu, Jiaxi; Sari, Hasan; Mingels, Clemens; Zeimpekis, Konstantinos; Prenosil, George; Wang, Yue; Zhang, Yu; Viscione, Marco; Sznitman, Raphael; Rominger, Axel; Li, Biao; Shi, Kuangyu (2022). Using domain knowledge for robust and generalizable deep learning-based CT-free PET attenuation and scatter correction. Nature Communications, 13(1), p. 5882. Springer Nature 10.1038/s41467-022-33562-9

Prenosil, George A; Hentschel, Michael; Weitzel, Thilo; Sari, Hasan; Shi, Kuangyu; Afshar-Oromieh, Ali; Rominger, Axel (2022). EARL compliance measurements on the biograph vision Quadra PET/CT system with a long axial field of view. EJNMMI Physics, 9(1), p. 26. Springer 10.1186/s40658-022-00455-1

Prenosil, George Amadeus; Sari, Hasan; Fürstner, Markus; Afshar-Oromieh, Ali; Shi, Kuangyu; Rominger, Axel; Hentschel, Michael (2022). Performance Characteristics of the Biograph Vision Quadra PET/CT system with long axial field of view using the NEMA NU 2-2018 Standard. Journal of nuclear medicine, 63(3), pp. 476-484. Society of Nuclear Medicine 10.2967/jnumed.121.261972

Alberts, Ian; Prenosil, George; Mingels, Clemens; Bohn, Karl Peter; Viscione, Marco; Sari, Hasan; Rominger, Axel; Afshar-Oromieh, Ali (2021). Feasibility of late acquisition [68Ga]Ga-PSMA-11 PET/CT using a long axial field-of-view PET/CT scanner for the diagnosis of recurrent prostate cancer—first clinical experiences. European journal of nuclear medicine and molecular imaging, 48(13), pp. 4456-4462. Springer-Verlag 10.1007/s00259-021-05438-5

Mingels, Clemens; Sachpekidis, Christos; Bohn, Karl P.; Hünermund, Jan-Niklas; Schepers, Robin; Fech, Viktor; Prenosil, George; Rominger, Axel; Afshar-Oromieh, Ali; Alberts, Ian (2021). The influence of colour scale in lesion detection and patient-based sensitivity in [68Ga]Ga-PSMA-PET/CT. Nuclear medicine communications, 42(5), pp. 495-502. Wolters Kluwer Health 10.1097/MNM.0000000000001364

Alberts, Ian; Hünermund, Jan-Niklas; Prenosil, George; Mingels, Clemens; Bohn, Karl Peter; Viscione, Marco; Sari, Hasan; Vollnberg, Bernd; Shi, Kuangyu; Afshar-Oromieh, Ali; Rominger, Axel (2021). Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT. European journal of nuclear medicine and molecular imaging, 48(8), pp. 2395-2404. Springer 10.1007/s00259-021-05282-7

Alberts, Ian; Sachpekidis, Christos; Prenosil, George; Viscione, Marco; Bohn, Karl Peter; Mingels, Clemens; Shi, Kuangyu; Afshar-Oromieh, Ali; Rominger, Axel (2021). Digital PET/CT allows for shorter acquisition protocols or reduced radiopharmaceutical dose in [18F]-FDG PET/CT. Annals of nuclear medicine, 35(4), pp. 485-492. Springer 10.1007/s12149-021-01588-6

Meier, Lorenz P; Läppchen, Tilman; Rominger, Axel; Hentschel, Michael; Prenosil, George A (2021). 3D Printing of Germanium-68 PET Phantoms. In: 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) (pp. 1-4). IEEE 10.1109/NSS/MIC44867.2021.9875768

Läppchen, Tilman; Meier, Lorenz P.; Fürstner, Markus; Prenosil, George; Krause, Thomas; Rominger, Axel; Klaeser, Bernd; Hentschel, Michael (2020). 3D printing of radioactive phantoms for nuclear medicine imaging. EJNMMI Physics, 7(1), p. 22. Springer 10.1186/s40658-020-00292-0

Alberts, Ian; Prenosil, George; Sachpekidis, Christos; Weitzel, Thilo; Shi, Kuangyu; Rominger, Axel; Afshar-Oromieh, Ali (2020). Digital versus analogue PET in [68Ga]Ga-PSMA-11 PET/CT for recurrent prostate cancer: a matched-pair comparison. European journal of nuclear medicine and molecular imaging, 47(3), pp. 614-623. Springer-Verlag 10.1007/s00259-019-04630-y

Alberts, Ian; Sachpekidis, Christos; Dijkstra, Lotte; Prenosil, George; Gourni, Eleni; Boxler, Silvan; Gross, Tobias; Thalmann, George; Rahbar, Kambiz; Rominger, Axel; Afshar-Oromieh, Ali (2020). The role of additional late PSMA-ligand PET/CT in the differentiation between lymph node metastases and ganglia. European journal of nuclear medicine and molecular imaging, 47(3), pp. 642-651. Springer-Verlag 10.1007/s00259-019-04552-9

Prenosil, George Amadeus; Weitzel, Thilo; Fürstner, Markus; Hentschel, Michael; Krause, Thomas; Cumming, Paul; Rominger, Axel; Klaeser, Bernd (2020). Towards guidelines to harmonize textural features in PET: Haralick textural features vary with image noise, but exposure-invariant domains enable comparable PET radiomics. PLoS ONE, 15(3), e0229560. Public Library of Science 10.1371/journal.pone.0229560

Bolisetty, Sreenath; Coray, Nastasia M.; Palika, Archana; Prenosil, George A.; Mezzenga, Raffaele (2020). Amyloid hybrid membranes for removal of clinical and nuclear radioactive wastewater. Environmental science. Water research & technology, 6(12), pp. 3249-3254. Royal Society of Chemistry 10.1039/D0EW00693A

Klaeser, Bernd; Prenosil, George; Hentschel, Michael; Fürstner, Markus; Krause, Thomas Michael; Rominger, Axel Oliver; Weitzel, Thilo (2018). Results of a nationwide phantom based PET-Survey in Switzerland before harmonization. European journal of nuclear medicine and molecular imaging, 45(S1), S59-S59. Springer-Verlag

Weitzel, Thilo; Prenosil, George; Hentschel, Michael; Fürstner, Markus; Krause, Thomas Michael; Rominger, Axel Oliver; Klaeser, Bernd (2018). Evaluation of Multi-Center PET/CT Quality Assurance: Multi-Paradigm Software Enables Automated PET Quality Control. European journal of nuclear medicine and molecular imaging, 45(S1), S310-S311. Springer-Verlag

Prenosil, George; Weitzel, Thilo; Hentschel, Michael; Krause, Thomas Michael; Rominger, Axel Oliver; Klaeser, Bernd (2018). Quantitative PET: Count Number Adaptations of Organ and Site specific Acquisition Protocols are a Key Determinant of comparable PET/CT Measurements. European journal of nuclear medicine and molecular imaging, 45(S1), S311-S312. Springer-Verlag

Prenosil, George A; Hentschel, Michael; Fürstner, Markus; Krause, Thomas Michael; Weitzel, Thilo; Klaeser, Bernd (2017). Technical Note: Transconvolution based equalization of positron energy effects for the use of 68 Ge/68 Ga phantoms in determining 18 F PET recovery. Medical physics, 44(7), pp. 3761-3766. American Association of Physicists in Medicine AAPM 10.1002/mp.12330

Fürstner, Markus; Hentschel, Michael; Spanjol, Petar Marko; Prenosil, George; Weidner, Sabine Edith; Krause, Thomas Michael; Klaeser, Bernd (2017). Technical Note: Determination of individual thyroid clearance effective half-life with a common handheld electronic dosimeter. Medical physics, 44(4), pp. 1558-1562. American Association of Physicists in Medicine AAPM 10.1002/mp.12161

Prenosil, George; Klaeser, Bernd; Hentschel, Michael; Fürstner, Markus; Berndt, Michael; Krause, Thomas Michael; Weitzel, Thilo (2016). Isotope independent determination of PET/CT modulation transfer functions from phantom measurements on spheres. Medical physics, 43(10), pp. 5767-5778. American Association of Physicists in Medicine AAPM 10.1118/1.4963217

Chang, Philip K.-Y.; Prenosil, George A.; Verbich, David; Gill, Raminder; McKinney, R. Anne (2014). Prolonged ampakine exposure prunes dendritic spines and increases presynaptic release probability for enhanced long-term potentiation in the hippocampus. European journal of neuroscience, 40(5), pp. 2766-2776. Blackwell Science 10.1111/ejn.12638

Gill, Raminder; Chang, Philip K.-Y.; Prenosil, George; Deane, Emily C.; McKinney, Rebecca A. (2013). Blocking brain-derived neurotrophic factor inhibits injury-induced hyperexcitability of hippocampal CA3 neurons. European journal of neuroscience, 38(11), pp. 3554-3566. Blackwell Science 10.1111/ejn.12367

Prenosil, George; Weitzel, Thilo; Hentschel, Michael; Klaeser, Bernd; Krause, Thomas Michael (2013). Transconvolution and the virtual positron emission tomograph--a new method for cross calibration in quantitative PET∕CT imaging. Medical physics, 40(6), 062503. American Association of Physicists in Medicine AAPM 10.1118/1.4805112

Provide Feedback